| contributor author | B. W. Friar | |
| contributor author | D. D. Glower | |
| contributor author | S. M. Marco | |
| date accessioned | 2017-05-08T22:59:01Z | |
| date available | 2017-05-08T22:59:01Z | |
| date copyright | March, 1975 | |
| date issued | 1975 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-26866#71_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/87695 | |
| description abstract | The dependence of ion-chamber current on the density of the filling gas has been investigated, experimentally and analytically, to explore the use of an ion chamber as a high-pressure gas densitometer. A flat-plate ion chamber with a self-contained beta-particle source (Sr90 -Y90 ) was used in experiments with methane, nitrogen, and carbon dioxide and for pressures up to 2000 psia and densities up to 9 lbm/ft3 . Over an appreciable density range, the linearity of the current-density response was good with a static sensitivity of about 10−10 amp/(lbm/ft3 ) and a reproducibility of ±0.5 percent. Variables which could be used to increase the static sensitivity and the linear range were identified. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Direct Measurement of High-Pressure Gas Density With an Ion-Chamber Densitometer | |
| type | Journal Paper | |
| journal volume | 97 | |
| journal issue | 1 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3447219 | |
| journal fristpage | 71 | |
| journal lastpage | 77 | |
| identifier eissn | 1528-901X | |
| keywords | Densitometers | |
| keywords | High pressure (Physics) | |
| keywords | Ionization chambers | |
| keywords | Density | |
| keywords | Beta particles | |
| keywords | Carbon dioxide | |
| keywords | Current density | |
| keywords | Flat plates | |
| keywords | Methane AND Nitrogen | |
| tree | Journal of Fluids Engineering:;1975:;volume( 097 ):;issue: 001 | |
| contenttype | Fulltext | |