Comments on L'Ambiance Plaza Lifting Collar/ShearheadsSource: Journal of Performance of Constructed Facilities:;1992:;Volume ( 006 ):;issue: 002Author:William McGuire
DOI: 10.1061/(ASCE)0887-3828(1992)6:2(78)Publisher: American Society of Civil Engineers
Abstract: The writer is engaged by the Occupational Safety and Health Administration (OSHA) to study the National Bureau of Standards (NBS) report on the L'Ambiance Plaza Building collapse and develop supplemental information for its use in legal proceedings. The study includes a review of the design of the lifting collar/shearhead assemblages. The paper is a summary of that review and the, writer's interpretation of subsequent evidence. Copies of design calculations and contract drawings are studied. In the paper, the absence of consideration of the effect of the lifting conditions on stresses in the arm channels in these calculations is noted. Questionable design details for welds connecting lifting angles to arm channels and header bars to header channels are also noted. The faulty condition of some of these welds as shown by lifting collar sectioning is illustrated. Evidence presented after the negotiated settlement of November 1988 reinforces the writer's finding that any of these deficiencies, and particularly the combination of unwise welds poorly executed, could have resulted in the initiation of the collapse. Recommendations for further investigation of these deficiencies are presented.
|
Collections
Show full item record
| contributor author | William McGuire | |
| date accessioned | 2017-05-08T22:21:05Z | |
| date available | 2017-05-08T22:21:05Z | |
| date copyright | May 1992 | |
| date issued | 1992 | |
| identifier other | 42838668.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/78405 | |
| description abstract | The writer is engaged by the Occupational Safety and Health Administration (OSHA) to study the National Bureau of Standards (NBS) report on the L'Ambiance Plaza Building collapse and develop supplemental information for its use in legal proceedings. The study includes a review of the design of the lifting collar/shearhead assemblages. The paper is a summary of that review and the, writer's interpretation of subsequent evidence. Copies of design calculations and contract drawings are studied. In the paper, the absence of consideration of the effect of the lifting conditions on stresses in the arm channels in these calculations is noted. Questionable design details for welds connecting lifting angles to arm channels and header bars to header channels are also noted. The faulty condition of some of these welds as shown by lifting collar sectioning is illustrated. Evidence presented after the negotiated settlement of November 1988 reinforces the writer's finding that any of these deficiencies, and particularly the combination of unwise welds poorly executed, could have resulted in the initiation of the collapse. Recommendations for further investigation of these deficiencies are presented. | |
| publisher | American Society of Civil Engineers | |
| title | Comments on L'Ambiance Plaza Lifting Collar/Shearheads | |
| type | Journal Paper | |
| journal volume | 6 | |
| journal issue | 2 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)0887-3828(1992)6:2(78) | |
| tree | Journal of Performance of Constructed Facilities:;1992:;Volume ( 006 ):;issue: 002 | |
| contenttype | Fulltext |