    Temperature Corrections for Time Domain Reflectometry Parameters

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2013:;Volume ( 139 ):;issue: 005
    Author:
    Sochan
    ,
    Jung
    ,
    Vincent P.
    ,
    Drnevich
    ,
    Majdi R.
    ,
    Abou Najm
    DOI: 10.1061/(ASCE)GT.1943-5606.0000794
    Publisher: American Society of Civil Engineers
    Abstract: The waveforms from time domain reflectometry (TDR) tests on soil depend on the temperature of the soil being tested. This study provides a discussion of, and the basis for, temperature corrections for the parameters measured in the TDR test for use in calculating water content and dry density of soil. This paper is a companion to one that provides the basis for an updated ASTM Standard, but does not cover temperature effects. A brief synopsis of the new methodology is provided herein to identify parameters that are sensitive to temperature of the soil being tested.
    • Download: (1.867Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Temperature Corrections for Time Domain Reflectometry Parameters

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/62606
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorSochan
    contributor authorJung
    contributor authorVincent P.
    contributor authorDrnevich
    contributor authorMajdi R.
    contributor authorAbou Najm
    date accessioned2017-05-08T21:47:49Z
    date available2017-05-08T21:47:49Z
    date copyrightMay 2013
    date issued2013
    identifier other%28asce%29gt%2E1943-5606%2E0000809.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62606
    description abstractThe waveforms from time domain reflectometry (TDR) tests on soil depend on the temperature of the soil being tested. This study provides a discussion of, and the basis for, temperature corrections for the parameters measured in the TDR test for use in calculating water content and dry density of soil. This paper is a companion to one that provides the basis for an updated ASTM Standard, but does not cover temperature effects. A brief synopsis of the new methodology is provided herein to identify parameters that are sensitive to temperature of the soil being tested.
    publisherAmerican Society of Civil Engineers
    titleTemperature Corrections for Time Domain Reflectometry Parameters
    typeJournal Paper
    journal volume139
    journal issue5
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0000794
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2013:;Volume ( 139 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian