    Full-Scale Testing of Open-Ended Steel Pipe Piles in Thick Varved Clayey Silt Deposits along the Delaware River in New Jersey

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2013:;Volume ( 139 ):;issue: 003
    Author:
    Yong
    ,
    Tan
    ,
    Guoming
    ,
    Lin
    DOI: 10.1061/(ASCE)GT.1943-5606.0000777
    Publisher: American Society of Civil Engineers
    Abstract: Although many studies have been done to investigate the axial behaviors of open-ended piles in sands, few studies have been reported for weak clayey silts. To develop reliable models for the design of open-ended steel-pipe piles driven into 29-m-thick varved clayey silt deposits, a series of full-scale field load tests including large-strain dynamic tests and static cyclic axial-compression-load tests was conducted on two groups of instrumented piles. Through analysis of the test data, soil parameters were back-calculated for estimation of pile capacities using the static-bearing-capacity formulas and cone-resistance-based methods. The comparisons between the calculated results and the field load test data demonstrated that the following considerations can be adopted in the design of static compression capacities of an open-ended pipe pile penetrating through thick varved clayey silts to end-bearing in dense cohesionless soils: (1) a fully plugged condition can be assumed, (2) cone resistance with an upper limit of 4,788 kPa (100 ksf) can be used for unit base resistance on the soil plug, and (3) exterior unit shaft resistance can be estimated using two-thirds of the total unit shaft resistance.
    • Download: (2.363Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Full-Scale Testing of Open-Ended Steel Pipe Piles in Thick Varved Clayey Silt Deposits along the Delaware River in New Jersey

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/62588
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorYong
    contributor authorTan
    contributor authorGuoming
    contributor authorLin
    date accessioned2017-05-08T21:47:47Z
    date available2017-05-08T21:47:47Z
    date copyrightMarch 2013
    date issued2013
    identifier other%28asce%29gt%2E1943-5606%2E0000792.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62588
    description abstractAlthough many studies have been done to investigate the axial behaviors of open-ended piles in sands, few studies have been reported for weak clayey silts. To develop reliable models for the design of open-ended steel-pipe piles driven into 29-m-thick varved clayey silt deposits, a series of full-scale field load tests including large-strain dynamic tests and static cyclic axial-compression-load tests was conducted on two groups of instrumented piles. Through analysis of the test data, soil parameters were back-calculated for estimation of pile capacities using the static-bearing-capacity formulas and cone-resistance-based methods. The comparisons between the calculated results and the field load test data demonstrated that the following considerations can be adopted in the design of static compression capacities of an open-ended pipe pile penetrating through thick varved clayey silts to end-bearing in dense cohesionless soils: (1) a fully plugged condition can be assumed, (2) cone resistance with an upper limit of 4,788 kPa (100 ksf) can be used for unit base resistance on the soil plug, and (3) exterior unit shaft resistance can be estimated using two-thirds of the total unit shaft resistance.
    publisherAmerican Society of Civil Engineers
    titleFull-Scale Testing of Open-Ended Steel Pipe Piles in Thick Varved Clayey Silt Deposits along the Delaware River in New Jersey
    typeJournal Paper
    journal volume139
    journal issue3
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0000777
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2013:;Volume ( 139 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian