    Full-Scale Impact Test of Four Traffic Barriers on Top of an Instrumented MSE Wall

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2010:;Volume ( 136 ):;issue: 003
    Author:
    K.-M. Kim
    ,
    J.-L. Briaud
    ,
    R. Bligh
    ,
    A. Abu-Odeh
    DOI: 10.1061/(ASCE)GT.1943-5606.0000232
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents the results of four full-scale impact tests against barriers placed on top of an instrumented mechanically stabilized earth (MSE) wall. The impact was created by a head-on collision of a 2,268-kg bogie going at about 32.2 km/h. The barriers were New Jersey and vertical wall barriers with a 1.37-m-wide moment slab in 9.14-m-long sections. The wall was 1.52 m high with one panel and two layers of reinforcement. The reinforcement was 2.44-m-long strips, 4.88-m-long strips, and 2.44-m-long bar mats. The backfill was crushed rock. The instrumentation consisted of accelerometers, strain gauges, contact switch, displacement targets, string lines, and high-speed cameras. The test was designed to represent a commonly used installation in current practice including an impact load on the barrier at least equal to 240 kN. Most of the barriers sustained significant damage but overall the behavior of the wall was satisfactory since the displacements of the panels were minimal (less than 25 mm) and the panel damage was acceptable except possibly in the case of the 4.88-m-long strips. The loads measured in the reinforcement indicate that the reinforcement was brought to its ultimate capacity for the duration of the impact but since the impact duration was so short and since the displacements of the panels were within tolerable limits of 25 mm, this is considered acceptable. The use of the longer strips (4.88-m-long strips) leads to slightly smaller panel displacements and higher panel stresses as evidenced by a bending crack in the panel. The 2.44-m-long strips permitted more displacement of the wall panels, but the magnitude of the displacement was considered to be tolerable. The measured maximum dynamic loads in the strips were found to be 3–5 times higher than the calculated maximum static loads by AASHTO guidelines.
    • Download: (1.368Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Full-Scale Impact Test of Four Traffic Barriers on Top of an Instrumented MSE Wall

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/62004
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorK.-M. Kim
    contributor authorJ.-L. Briaud
    contributor authorR. Bligh
    contributor authorA. Abu-Odeh
    date accessioned2017-05-08T21:46:40Z
    date available2017-05-08T21:46:40Z
    date copyrightMarch 2010
    date issued2010
    identifier other%28asce%29gt%2E1943-5606%2E0000249.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/62004
    description abstractThis paper presents the results of four full-scale impact tests against barriers placed on top of an instrumented mechanically stabilized earth (MSE) wall. The impact was created by a head-on collision of a 2,268-kg bogie going at about 32.2 km/h. The barriers were New Jersey and vertical wall barriers with a 1.37-m-wide moment slab in 9.14-m-long sections. The wall was 1.52 m high with one panel and two layers of reinforcement. The reinforcement was 2.44-m-long strips, 4.88-m-long strips, and 2.44-m-long bar mats. The backfill was crushed rock. The instrumentation consisted of accelerometers, strain gauges, contact switch, displacement targets, string lines, and high-speed cameras. The test was designed to represent a commonly used installation in current practice including an impact load on the barrier at least equal to 240 kN. Most of the barriers sustained significant damage but overall the behavior of the wall was satisfactory since the displacements of the panels were minimal (less than 25 mm) and the panel damage was acceptable except possibly in the case of the 4.88-m-long strips. The loads measured in the reinforcement indicate that the reinforcement was brought to its ultimate capacity for the duration of the impact but since the impact duration was so short and since the displacements of the panels were within tolerable limits of 25 mm, this is considered acceptable. The use of the longer strips (4.88-m-long strips) leads to slightly smaller panel displacements and higher panel stresses as evidenced by a bending crack in the panel. The 2.44-m-long strips permitted more displacement of the wall panels, but the magnitude of the displacement was considered to be tolerable. The measured maximum dynamic loads in the strips were found to be 3–5 times higher than the calculated maximum static loads by AASHTO guidelines.
    publisherAmerican Society of Civil Engineers
    titleFull-Scale Impact Test of Four Traffic Barriers on Top of an Instrumented MSE Wall
    typeJournal Paper
    journal volume136
    journal issue3
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0000232
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2010:;Volume ( 136 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian