YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Geotechnical and Geoenvironmental Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Geotechnical and Geoenvironmental Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Bayesian Model Calibration Using Geotechnical Centrifuge Tests

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2009:;Volume ( 135 ):;issue: 002
    Author:
    L. L. Zhang
    ,
    W. H. Tang
    ,
    L. M. Zhang
    DOI: 10.1061/(ASCE)1090-0241(2009)135:2(291)
    Publisher: American Society of Civil Engineers
    Abstract: The predicted performance using a geotechnical prediction model is expected to deviate from reality. A practical approach to assess the model error is through calibration with observed performances in physical model tests. In this paper, a Bayesian framework of model calibration using centrifuge modeling tests is proposed and the procedure of model calibration is illustrated. Two centrifuge tests conducted to investigate the performance of soil slopes under rainfall conditions are used to calibrate a coupled hydromechanical analysis model. It is found that for centrifuge tests with different levels of soil variability, the test with a smaller variability of soil properties is more efficient for model calibration. According to the concept of random field, a centrifuge model with a larger model size and accelerated to a lower acceleration is better for model calibration. When the discrepancy between the performance interpreted from the centrifuge model and the field performance is small, the improvement of the reliability estimation for a new slope is significant. However, when there is little information about the discrepancy, the reliability estimation cannot be significantly improved by the information from centrifuge modeling. The proposed procedure is shown to be able to quantify the calibration effects of centrifuge tests and may be used to achieve a more reliable calibration.
    • Download: (245.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Bayesian Model Calibration Using Geotechnical Centrifuge Tests

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/53465
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorL. L. Zhang
    contributor authorW. H. Tang
    contributor authorL. M. Zhang
    date accessioned2017-05-08T21:29:26Z
    date available2017-05-08T21:29:26Z
    date copyrightFebruary 2009
    date issued2009
    identifier other%28asce%291090-0241%282009%29135%3A2%28291%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53465
    description abstractThe predicted performance using a geotechnical prediction model is expected to deviate from reality. A practical approach to assess the model error is through calibration with observed performances in physical model tests. In this paper, a Bayesian framework of model calibration using centrifuge modeling tests is proposed and the procedure of model calibration is illustrated. Two centrifuge tests conducted to investigate the performance of soil slopes under rainfall conditions are used to calibrate a coupled hydromechanical analysis model. It is found that for centrifuge tests with different levels of soil variability, the test with a smaller variability of soil properties is more efficient for model calibration. According to the concept of random field, a centrifuge model with a larger model size and accelerated to a lower acceleration is better for model calibration. When the discrepancy between the performance interpreted from the centrifuge model and the field performance is small, the improvement of the reliability estimation for a new slope is significant. However, when there is little information about the discrepancy, the reliability estimation cannot be significantly improved by the information from centrifuge modeling. The proposed procedure is shown to be able to quantify the calibration effects of centrifuge tests and may be used to achieve a more reliable calibration.
    publisherAmerican Society of Civil Engineers
    titleBayesian Model Calibration Using Geotechnical Centrifuge Tests
    typeJournal Paper
    journal volume135
    journal issue2
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)1090-0241(2009)135:2(291)
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2009:;Volume ( 135 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian