    Experimental Investigations of Response of Suction Caissons to Transient Vertical Loading

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2002:;Volume ( 128 ):;issue: 011
    Author:
    Byron W. Byrne
    ,
    Guy T. Houlsby
    DOI: 10.1061/(ASCE)1090-0241(2002)128:11(926)
    Publisher: American Society of Civil Engineers
    Abstract: Suction caissons are a relatively new design being considered for use as foundations in a wide variety of offshore applications. They are unusual in that, in contrast with the development of offshore piling, there is no onshore experience that can be used as the basis for the development of designs. It is therefore essential to identify key behavioral patterns and mechanisms that govern capacity under a wide variety of loading regimes, particularly those derived from the cyclic wave loading. The object here is to establish a broad framework of response. More detailed work specific to a site or project would be required for detailed design. This paper describes experimental investigations into the vertical loading response of a suction caisson foundation. The experiments are carried out on the laboratory floor using a sophisticated three-degree-of-freedom loading rig. The caissons are embedded in sand saturated with viscous silicon oil so that modeled drainage times are representative of typical offshore conditions. The experiments involve cyclic loading about different mean loads, including cycling into tension and monotonic loading at different rates. The relationship between the cyclic loading and monotonic loading is explored. One of the key conclusions from the results is that serviceability requirements will dictate design rather than capacity. Perhaps surprisingly, for the experiments undertaken, the rate of loading had little effect on the response.
    • Download: (687.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Investigations of Response of Suction Caissons to Transient Vertical Loading

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/52117
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorByron W. Byrne
    contributor authorGuy T. Houlsby
    date accessioned2017-05-08T21:27:21Z
    date available2017-05-08T21:27:21Z
    date copyrightNovember 2002
    date issued2002
    identifier other%28asce%291090-0241%282002%29128%3A11%28926%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/52117
    description abstractSuction caissons are a relatively new design being considered for use as foundations in a wide variety of offshore applications. They are unusual in that, in contrast with the development of offshore piling, there is no onshore experience that can be used as the basis for the development of designs. It is therefore essential to identify key behavioral patterns and mechanisms that govern capacity under a wide variety of loading regimes, particularly those derived from the cyclic wave loading. The object here is to establish a broad framework of response. More detailed work specific to a site or project would be required for detailed design. This paper describes experimental investigations into the vertical loading response of a suction caisson foundation. The experiments are carried out on the laboratory floor using a sophisticated three-degree-of-freedom loading rig. The caissons are embedded in sand saturated with viscous silicon oil so that modeled drainage times are representative of typical offshore conditions. The experiments involve cyclic loading about different mean loads, including cycling into tension and monotonic loading at different rates. The relationship between the cyclic loading and monotonic loading is explored. One of the key conclusions from the results is that serviceability requirements will dictate design rather than capacity. Perhaps surprisingly, for the experiments undertaken, the rate of loading had little effect on the response.
    publisherAmerican Society of Civil Engineers
    titleExperimental Investigations of Response of Suction Caissons to Transient Vertical Loading
    typeJournal Paper
    journal volume128
    journal issue11
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)1090-0241(2002)128:11(926)
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2002:;Volume ( 128 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian