Show simple item record

contributor authorFerreira, Mariana
contributor authorCarvalho, Violeta
contributor authorPinho, Diana
contributor authorLima, Rui
contributor authorTeixeira, Senhorinha
contributor authorSoares, Armando A.
date accessioned2025-08-20T09:21:55Z
date available2025-08-20T09:21:55Z
date copyright2/28/2025 12:00:00 AM
date issued2025
identifier issn2572-7958
identifier otherjesmdt_008_03_031013.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308158
description abstractNumerical simulation of carotid artery bifurcation is essential for understanding blood flow dynamics in this complex region, aiding in identifying patterns associated with stress points and atherosclerosis risk. This information is valuable for developing preventive and therapeutic strategies for vascular diseases, as well as optimizing medical devices and surgical interventions. Simulations offer insights into blood flow at the carotid bifurcation, advancing biomedical research and clinical applications. Engineers use computational tools to address multiphase flow complexities, supporting efficient device design, quick simulations, and cost-effective exploration of fluid dynamics across phases. In this study, carotid artery hemodynamics were analyzed using a biphasic blood model (plasma and erythrocytes) via ansys software. Wall shear stresses (WSSs), strain rates (SRs), and red blood cells (RBCs) distribution were examined. Results showed that while strain rates were similar in both phases, wall shear stresses differed: plasma shear stress was about 7.17 times higher than that due to RBCs, and strain rates in plasma were approximately 2.2 times higher than in RBCs. Additionally, the pressure in RBCs was about 0.39% higher than in plasma. These findings highlight distinct hemodynamic behaviors in each phase, contributing to a deeper understanding of blood flow mechanics at the carotid bifurcation.
publisherThe American Society of Mechanical Engineers (ASME)
titleComputational Simulation of the Hemodynamics in an Anatomic Carotid Artery Model: A Biphasic Blood Model
typeJournal Paper
journal volume8
journal issue3
journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
identifier doi10.1115/1.4067516
journal fristpage31013-1
journal lastpage31013-12
page12
treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2025:;volume( 008 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record