YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Automatic Fungal Glucan Analyzer: For the Rapid Laboratory Testing

    Source: Journal of Medical Devices:;2025:;volume( 019 ):;issue: 003::page 31001-1
    Author:
    Wu, Yamei
    ,
    Liu, Zeyuan
    ,
    Zhang, Yu
    ,
    Liu, Chunlong
    ,
    Zhu, Guimei
    ,
    Zhong, Chen
    DOI: 10.1115/1.4068327
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Invasive fungal infections (IFIs) have a high mortality rate, especially in the context of invasive treatments such as the use of high-intensity immunosuppressive drugs and indwelling catheters. It is crucial to have a sensitive instrument for rapid laboratory testing to detect early invasive fungal disease (IFD). Therefore, we propose an automatic fungal dextran analyzer that streamlines sample addition, mixing, and result processing, reducing cross-contamination and enhancing operational efficiency. This analyzer utilizes human serum as the sample and offers rapid point-of-care testing (POCT) for IFD without the need for manual intervention. Each individual sample can be processed in just 45 min, and the instrument has the capacity to handle 24 patient specimens within an hour. To address optoelectronic noise concerns, our instrument's algorithm design incorporates both sliding average filtering and a modified version of the least squares method. The application of these techniques significantly enhances the algorithm's accuracy, resulting in an impressive improvement from 95.82% to 99.98%. The instrument underwent clinical testing using serum samples obtained from 130 subjects. The study findings revealed that the instrument effectively facilitated early diagnosis of IFD, thereby considerably improving the efficiency of the testing process.
    • Download: (1.731Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Automatic Fungal Glucan Analyzer: For the Rapid Laboratory Testing

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4308112
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorWu, Yamei
    contributor authorLiu, Zeyuan
    contributor authorZhang, Yu
    contributor authorLiu, Chunlong
    contributor authorZhu, Guimei
    contributor authorZhong, Chen
    date accessioned2025-08-20T09:20:21Z
    date available2025-08-20T09:20:21Z
    date copyright5/5/2025 12:00:00 AM
    date issued2025
    identifier issn1932-6181
    identifier othermed_019_03_031001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4308112
    description abstractInvasive fungal infections (IFIs) have a high mortality rate, especially in the context of invasive treatments such as the use of high-intensity immunosuppressive drugs and indwelling catheters. It is crucial to have a sensitive instrument for rapid laboratory testing to detect early invasive fungal disease (IFD). Therefore, we propose an automatic fungal dextran analyzer that streamlines sample addition, mixing, and result processing, reducing cross-contamination and enhancing operational efficiency. This analyzer utilizes human serum as the sample and offers rapid point-of-care testing (POCT) for IFD without the need for manual intervention. Each individual sample can be processed in just 45 min, and the instrument has the capacity to handle 24 patient specimens within an hour. To address optoelectronic noise concerns, our instrument's algorithm design incorporates both sliding average filtering and a modified version of the least squares method. The application of these techniques significantly enhances the algorithm's accuracy, resulting in an impressive improvement from 95.82% to 99.98%. The instrument underwent clinical testing using serum samples obtained from 130 subjects. The study findings revealed that the instrument effectively facilitated early diagnosis of IFD, thereby considerably improving the efficiency of the testing process.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAutomatic Fungal Glucan Analyzer: For the Rapid Laboratory Testing
    typeJournal Paper
    journal volume19
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4068327
    journal fristpage31001-1
    journal lastpage31001-10
    page10
    treeJournal of Medical Devices:;2025:;volume( 019 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian