Thermal Performance Investigation of Vapor Chamber Under Partial Heating and Different Heat Flux Conditions: Effects of Inclination AngleSource: ASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 001::page 11602-1Author:Varol, Yasin
,
Oztop, Hakan F.
,
Tamdoğan, Enes
,
Parlak, Murat
,
Şenocak, Şafak Melih
,
Coşanay, Hakan
DOI: 10.1115/1.4066664Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The need for cooling technologies increases tremendously with raising demand on the powerful and compact electronics. There, it pushes the research and technology to the new investigations on varying heat transfer mechanisms and devices. While one of these devices is vapor chamber (VC), an experimental study has been carried out to investigate the heat transfer performance of a VC under partial heating, varying heat fluxes, and different inclination angles for different temperatures, in the current study. For this purpose, a VC with a dimension of 90 mm × 90 mm × 3 mm is evaluated via its resulting thermal resistance, performance, and the temperature distribution over the VC surface. There, the limited effect of inclination angle is observed on the performance, while the highest change is obtained with decreasing local heating surface area, thus increasing heat fluxes. Moreover, this trend is seen almost similar with a reasonable shift up or down according to the different temperature differences.
|
Collections
Show full item record
contributor author | Varol, Yasin | |
contributor author | Oztop, Hakan F. | |
contributor author | Tamdoğan, Enes | |
contributor author | Parlak, Murat | |
contributor author | Şenocak, Şafak Melih | |
contributor author | Coşanay, Hakan | |
date accessioned | 2025-04-21T10:13:43Z | |
date available | 2025-04-21T10:13:43Z | |
date copyright | 10/18/2024 12:00:00 AM | |
date issued | 2024 | |
identifier issn | 2832-8450 | |
identifier other | ht_147_01_011602.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4305752 | |
description abstract | The need for cooling technologies increases tremendously with raising demand on the powerful and compact electronics. There, it pushes the research and technology to the new investigations on varying heat transfer mechanisms and devices. While one of these devices is vapor chamber (VC), an experimental study has been carried out to investigate the heat transfer performance of a VC under partial heating, varying heat fluxes, and different inclination angles for different temperatures, in the current study. For this purpose, a VC with a dimension of 90 mm × 90 mm × 3 mm is evaluated via its resulting thermal resistance, performance, and the temperature distribution over the VC surface. There, the limited effect of inclination angle is observed on the performance, while the highest change is obtained with decreasing local heating surface area, thus increasing heat fluxes. Moreover, this trend is seen almost similar with a reasonable shift up or down according to the different temperature differences. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Thermal Performance Investigation of Vapor Chamber Under Partial Heating and Different Heat Flux Conditions: Effects of Inclination Angle | |
type | Journal Paper | |
journal volume | 147 | |
journal issue | 1 | |
journal title | ASME Journal of Heat and Mass Transfer | |
identifier doi | 10.1115/1.4066664 | |
journal fristpage | 11602-1 | |
journal lastpage | 11602-8 | |
page | 8 | |
tree | ASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 001 | |
contenttype | Fulltext |