    Thermal Hydraulic Performance and Characteristics of a Microchannel Heat Exchanger: Experimental and Numerical Investigations

    Source: ASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 002::page 21801-1
    Author:
    Pandey, Vishwas Kumar
    ,
    Choudhary, Vishwjeet
    ,
    Ranganayakulu, Chennu
    ,
    A. M., Aneesh
    DOI: 10.1115/1.4067012
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents extensive fluid flow and Heat Transfer studies conducted through an experimental setup followed by a detailed three-dimensional (3D) numerical analysis of the same setup using a commercial package for computational fluid dynamics (CFD), known as cfd-ace® for additive-manufactured counterflow AlSi10 Mg microchannel heat exchangers (MCHEs). A detailed 3D computational model of the experimentally tested MCHEs was built and analyzed using the commercial software cfd-ace® for the same experimentally tested operating conditions. The computational model results are in good agreement with experimental data of tested MCHE within +2% to +7% and ∼0% to −13.5% variation for cold and hot fluids for the entire set of design of experiments (DoEs). This percentage disagreement may be due to various factors, such as manufacturing deviation within tolerance, longitudinal conduction, variation in the thermal conductivity of the material after heat treatment, variation in environmental temperature, sensor deviation, and surface roughness of internal channels. Instead of Stainless steel (SST), AlSi10 Mg was used because of its lower manufacturing cost because AlSi10 Mg was lighter than SST, though its thermal conductivity is almost ∼8–10 times more than that of SST. A higher thermal conductivity is not good for MCHEs because it leads to higher longitudinal conduction, which eventually degrades the performance of MCHEs in terms of effectiveness. MCHE effectiveness is also reduced by ∼12% to 18% owing to longitudinal conduction from ideal effectiveness.
    • Download: (6.406Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Thermal Hydraulic Performance and Characteristics of a Microchannel Heat Exchanger: Experimental and Numerical Investigations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4305624
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorPandey, Vishwas Kumar
    contributor authorChoudhary, Vishwjeet
    contributor authorRanganayakulu, Chennu
    contributor authorA. M., Aneesh
    date accessioned2025-04-21T10:09:50Z
    date available2025-04-21T10:09:50Z
    date copyright11/20/2024 12:00:00 AM
    date issued2024
    identifier issn2832-8450
    identifier otherht_147_02_021801.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4305624
    description abstractThis paper presents extensive fluid flow and Heat Transfer studies conducted through an experimental setup followed by a detailed three-dimensional (3D) numerical analysis of the same setup using a commercial package for computational fluid dynamics (CFD), known as cfd-ace® for additive-manufactured counterflow AlSi10 Mg microchannel heat exchangers (MCHEs). A detailed 3D computational model of the experimentally tested MCHEs was built and analyzed using the commercial software cfd-ace® for the same experimentally tested operating conditions. The computational model results are in good agreement with experimental data of tested MCHE within +2% to +7% and ∼0% to −13.5% variation for cold and hot fluids for the entire set of design of experiments (DoEs). This percentage disagreement may be due to various factors, such as manufacturing deviation within tolerance, longitudinal conduction, variation in the thermal conductivity of the material after heat treatment, variation in environmental temperature, sensor deviation, and surface roughness of internal channels. Instead of Stainless steel (SST), AlSi10 Mg was used because of its lower manufacturing cost because AlSi10 Mg was lighter than SST, though its thermal conductivity is almost ∼8–10 times more than that of SST. A higher thermal conductivity is not good for MCHEs because it leads to higher longitudinal conduction, which eventually degrades the performance of MCHEs in terms of effectiveness. MCHE effectiveness is also reduced by ∼12% to 18% owing to longitudinal conduction from ideal effectiveness.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThermal Hydraulic Performance and Characteristics of a Microchannel Heat Exchanger: Experimental and Numerical Investigations
    typeJournal Paper
    journal volume147
    journal issue2
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4067012
    journal fristpage21801-1
    journal lastpage21801-18
    page18
    treeASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian