A Wearable Multichannel Electrical Stimulator for Tremor SuppressionSource: Journal of Medical Devices:;2024:;volume( 019 ):;issue: 001::page 14501-1DOI: 10.1115/1.4066678Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Pathological wrist and finger tremors can be mitigated by out-of-phase stimulation of the sensory nerves in the flexor and extensor muscles. This study endeavors to develop a portable, multichannel electrical stimulator designed to deliver high-frequency, low-intensity, biphasic charge-balanced current pulses within a practical load range to effectively suppress wrist and finger tremors. The circuit architecture integrates an Arduino Nanomicrocontroller, a four-channel digital potentiometer, and four Howland current pumps. The Howland current pump, employing an operational amplifier, generates bipolar currents by accepting bipolar voltages, whereas the digital potentiometer offers programmable bipolar voltages via its wiper terminals. Experimental results indicate that the pulse frequency can be adjusted between 50 Hz and 200 Hz, and the current level can be modulated within a range of −10 mA to +10 mA, with load resistance spanning 100 Ω to 1.3 kΩ. This portable and multichannel device is effective in delivering high-frequency, low-intensity sensory nerve stimulation through programmable biphasic charge-balanced current pulses. The proposed stimulator has the potential to enable adaptive muscle activation, thereby initiating, promoting, and generating movements, and facilitating interactive in-home neurorehabilitation for disabled patients. The portability and programmability of this device make it a promising tool for personalized tremor management and rehabilitation, enhancing the quality of life for individuals with motor impairments.
|
Collections
Show full item record
contributor author | Zhang, Tongpo | |
contributor author | Ying, Huiqian | |
date accessioned | 2025-04-21T10:05:08Z | |
date available | 2025-04-21T10:05:08Z | |
date copyright | 10/22/2024 12:00:00 AM | |
date issued | 2024 | |
identifier issn | 1932-6181 | |
identifier other | med_019_01_014501.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4305465 | |
description abstract | Pathological wrist and finger tremors can be mitigated by out-of-phase stimulation of the sensory nerves in the flexor and extensor muscles. This study endeavors to develop a portable, multichannel electrical stimulator designed to deliver high-frequency, low-intensity, biphasic charge-balanced current pulses within a practical load range to effectively suppress wrist and finger tremors. The circuit architecture integrates an Arduino Nanomicrocontroller, a four-channel digital potentiometer, and four Howland current pumps. The Howland current pump, employing an operational amplifier, generates bipolar currents by accepting bipolar voltages, whereas the digital potentiometer offers programmable bipolar voltages via its wiper terminals. Experimental results indicate that the pulse frequency can be adjusted between 50 Hz and 200 Hz, and the current level can be modulated within a range of −10 mA to +10 mA, with load resistance spanning 100 Ω to 1.3 kΩ. This portable and multichannel device is effective in delivering high-frequency, low-intensity sensory nerve stimulation through programmable biphasic charge-balanced current pulses. The proposed stimulator has the potential to enable adaptive muscle activation, thereby initiating, promoting, and generating movements, and facilitating interactive in-home neurorehabilitation for disabled patients. The portability and programmability of this device make it a promising tool for personalized tremor management and rehabilitation, enhancing the quality of life for individuals with motor impairments. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | A Wearable Multichannel Electrical Stimulator for Tremor Suppression | |
type | Journal Paper | |
journal volume | 19 | |
journal issue | 1 | |
journal title | Journal of Medical Devices | |
identifier doi | 10.1115/1.4066678 | |
journal fristpage | 14501-1 | |
journal lastpage | 14501-7 | |
page | 7 | |
tree | Journal of Medical Devices:;2024:;volume( 019 ):;issue: 001 | |
contenttype | Fulltext |