Insights Into Pool Boiling Heat Transfer on Minichannel Surfaces Through Point and Field MeasurementsSource: ASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 002::page 21601-1Author:Dhanalakota, Praveen
,
Rahaman, Md Motiur
,
Mahapatra, Pallab Sinha
,
Anand, A. R.
,
Das, Sarit Kumar
,
Pattamatta, Arvind
DOI: 10.1115/1.4066776Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this study, saturated pool boiling experiments were conducted on copper minichannel and flat surfaces at atmospheric pressure using water as the working fluid. The heat transfer performance was assessed through point measurements with a heater block, cartridge heaters, and thermocouples, as well as field measurements using a thin-foil heater and infrared thermography. Two copper minichannel surfaces with square cross sections of 1 mm (minichannel-1) and 2 mm (minichannel-2) side lengths were tested and compared to a flat surface. Minichannel-1 and minichannel-2 enhanced the critical heat flux (CHF) by 17% and 45%, respectively, and improved the heat transfer coefficient by 24–40% and 51–75%, respectively, compared to the flat surface. Minichannel-2 exhibited the lowest and most uniform boiling surface temperature, making it the best performer among the three. There was no significant change in departure frequency among the surfaces, and no significant change in departure diameter for the flat surface and minichannel-1. However, minichannel-2 had lower departure diameters due to its deeper channels, which prevented bubble coalescence and maintained low departure diameters. Additionally, minichannel-2 delayed vapor film formation by breaking it with its deeper fins, thereby improving CHF and slightly enhancing bubble dynamics. The enhancement in boiling heat transfer is primarily attributed to the increased surface area provided by the minichannels, with a minor contribution from improved bubble dynamics. However, the dominant factor in enhancing pool boiling heat transfer on minichannel surfaces is the increase in surface area.
|
Collections
Show full item record
contributor author | Dhanalakota, Praveen | |
contributor author | Rahaman, Md Motiur | |
contributor author | Mahapatra, Pallab Sinha | |
contributor author | Anand, A. R. | |
contributor author | Das, Sarit Kumar | |
contributor author | Pattamatta, Arvind | |
date accessioned | 2025-04-21T10:02:05Z | |
date available | 2025-04-21T10:02:05Z | |
date copyright | 11/15/2024 12:00:00 AM | |
date issued | 2024 | |
identifier issn | 2832-8450 | |
identifier other | ht_147_02_021601.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4305358 | |
description abstract | In this study, saturated pool boiling experiments were conducted on copper minichannel and flat surfaces at atmospheric pressure using water as the working fluid. The heat transfer performance was assessed through point measurements with a heater block, cartridge heaters, and thermocouples, as well as field measurements using a thin-foil heater and infrared thermography. Two copper minichannel surfaces with square cross sections of 1 mm (minichannel-1) and 2 mm (minichannel-2) side lengths were tested and compared to a flat surface. Minichannel-1 and minichannel-2 enhanced the critical heat flux (CHF) by 17% and 45%, respectively, and improved the heat transfer coefficient by 24–40% and 51–75%, respectively, compared to the flat surface. Minichannel-2 exhibited the lowest and most uniform boiling surface temperature, making it the best performer among the three. There was no significant change in departure frequency among the surfaces, and no significant change in departure diameter for the flat surface and minichannel-1. However, minichannel-2 had lower departure diameters due to its deeper channels, which prevented bubble coalescence and maintained low departure diameters. Additionally, minichannel-2 delayed vapor film formation by breaking it with its deeper fins, thereby improving CHF and slightly enhancing bubble dynamics. The enhancement in boiling heat transfer is primarily attributed to the increased surface area provided by the minichannels, with a minor contribution from improved bubble dynamics. However, the dominant factor in enhancing pool boiling heat transfer on minichannel surfaces is the increase in surface area. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Insights Into Pool Boiling Heat Transfer on Minichannel Surfaces Through Point and Field Measurements | |
type | Journal Paper | |
journal volume | 147 | |
journal issue | 2 | |
journal title | ASME Journal of Heat and Mass Transfer | |
identifier doi | 10.1115/1.4066776 | |
journal fristpage | 21601-1 | |
journal lastpage | 21601-14 | |
page | 14 | |
tree | ASME Journal of Heat and Mass Transfer:;2024:;volume( 147 ):;issue: 002 | |
contenttype | Fulltext |