Show simple item record

contributor authorBerger, Daniel Michael
contributor authorSehrt, Jan T.
contributor authorBrinkmann, Thomas
contributor authorHenrichs, Niclas Norman
contributor authorBilec, Oguzhan
contributor authorFuchs, Karl-Hermann
contributor authorMeining, Alexander
date accessioned2024-12-24T19:14:48Z
date available2024-12-24T19:14:48Z
date copyright7/30/2024 12:00:00 AM
date issued2024
identifier issn1932-6181
identifier othermed_018_03_031005.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303575
description abstractThe development of medical products begins with the “in silico” phase, where the development and simulation of new stent types are carried out. This is followed by the “in vitro” phase. Here, tests are done in a test stand to obtain initial conclusions about the interaction of the environment. The approval process is completed in the “in vivo” phase, where testing in living beings happen. Here, preclinical studies are carried out in animals first, followed by clinical studies on patients. A big part of the development fails in this final phase, as this is where the interactions of all influences from the stent environment are investigated. Since this not only causes high costs for the developers but also unnecessarily destroys living resources in animal studies, this publication describes the development of a test stand called “Swallow-Sim” that superimposes the mechanical influences of the esophagus, the chemical stress caused by hydrochloric acid and increased body temperature. Furthermore, tests of the acting pressures are carried out using esophageal manometry, a temperature test of the test stand and a test run of the gastric juice. At the end of this publication, the results are evaluated with a six-week test of a Nickel Titanium Naval Ordnance Laboratory stent, which loses much of its mechanical properties and is partially destroyed by the load. The results show a clear correlation with the findings from reality. The test stand should be further optimized and examined in more detail in further tests and subjected to a reality check.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Development of a Novel Peristaltic Test Stand “Swallow-Sim” for the Mechanical Evaluation of Esophageal Stents
typeJournal Paper
journal volume18
journal issue3
journal titleJournal of Medical Devices
identifier doi10.1115/1.4065906
journal fristpage31005-1
journal lastpage31005-10
page10
treeJournal of Medical Devices:;2024:;volume( 018 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record