Surface Reaction of Electroosmotic Flow-Driven Free Antigens With Immobilized Magnetic-Microbeads-Tagged-Antibodies in MicrochannelsSource: Journal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 009::page 91003-1DOI: 10.1115/1.4065138Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Immunoassays based on reactions between target pathogen (antigen; Ag) and antibody (Ab) are frequently used for Ag detection. An external magnetic field was used to immobilize magnetic microbeads-tagged-antibodies (mMB-Ab) on the surface of a microchannel in the capture zone. The mMB-Ab was subsequently used for Ag detection. The objective of this numerical study, with experimental validation, is to assess the surface reaction between mMB-Ab and Ag in the presence of electro-osmotic flow (EOF). First, immobilization of mMB-Ab complex in the wall of the capture zone was achieved. Subsequently, the Ag was transported by EOF toward the capture zone to bind with the immobilized mMB-Ab. Lastly, mMB-Ab:Ag complex was formed and immobilized in the capture zone. A finite volume solver was used to implement the above steps. The surface reaction between the mMB-Ab and Ag was investigated in the presence of electric fields (E): 150 V/cm–450 V/cm and Ag concentrations: 0.001 M–1000 M. The depletion of mMB-Ab increases with time as the E decreases. Furthermore, as the concentration of Ag decreases, the depletion of mMB-Ab increases with time. These results quantify the detection of Ag using the EOF device; thus, signifying its potential for rapid throughput screening of Ag. This platform technology can lead to the development of portable devices for the detection of target cells, pathogens, and biomolecules for testing water systems, biological fluids, and biochemicals.
|
Collections
Show full item record
contributor author | Ajiboye, Israel O. | |
contributor author | Banerjee, Rupak K. | |
date accessioned | 2024-12-24T19:11:26Z | |
date available | 2024-12-24T19:11:26Z | |
date copyright | 4/8/2024 12:00:00 AM | |
date issued | 2024 | |
identifier issn | 0148-0731 | |
identifier other | bio_146_09_091003.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4303460 | |
description abstract | Immunoassays based on reactions between target pathogen (antigen; Ag) and antibody (Ab) are frequently used for Ag detection. An external magnetic field was used to immobilize magnetic microbeads-tagged-antibodies (mMB-Ab) on the surface of a microchannel in the capture zone. The mMB-Ab was subsequently used for Ag detection. The objective of this numerical study, with experimental validation, is to assess the surface reaction between mMB-Ab and Ag in the presence of electro-osmotic flow (EOF). First, immobilization of mMB-Ab complex in the wall of the capture zone was achieved. Subsequently, the Ag was transported by EOF toward the capture zone to bind with the immobilized mMB-Ab. Lastly, mMB-Ab:Ag complex was formed and immobilized in the capture zone. A finite volume solver was used to implement the above steps. The surface reaction between the mMB-Ab and Ag was investigated in the presence of electric fields (E): 150 V/cm–450 V/cm and Ag concentrations: 0.001 M–1000 M. The depletion of mMB-Ab increases with time as the E decreases. Furthermore, as the concentration of Ag decreases, the depletion of mMB-Ab increases with time. These results quantify the detection of Ag using the EOF device; thus, signifying its potential for rapid throughput screening of Ag. This platform technology can lead to the development of portable devices for the detection of target cells, pathogens, and biomolecules for testing water systems, biological fluids, and biochemicals. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Surface Reaction of Electroosmotic Flow-Driven Free Antigens With Immobilized Magnetic-Microbeads-Tagged-Antibodies in Microchannels | |
type | Journal Paper | |
journal volume | 146 | |
journal issue | 9 | |
journal title | Journal of Biomechanical Engineering | |
identifier doi | 10.1115/1.4065138 | |
journal fristpage | 91003-1 | |
journal lastpage | 91003-11 | |
page | 11 | |
tree | Journal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 009 | |
contenttype | Fulltext |