YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • ASME Journal of Heat and Mass Transfer
    • View Item
    •   YE&T Library
    • ASME
    • ASME Journal of Heat and Mass Transfer
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Study of a Novel Helix-Shaped Oscillating Heat Pipe and Design Parameters for Flow Stabilization

    Source: ASME Journal of Heat and Mass Transfer:;2024:;volume( 146 ):;issue: 010::page 103001-1
    Author:
    Pawlick, Max
    ,
    Peterson, G. P.
    DOI: 10.1115/1.4065576
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A novel helix-shaped oscillating heat pipe (OHP) designed for enhanced heat transfer in thermal management and heat recovery systems was studied experimentally. Two orientations were explored: side-heated, which is the intended orientation in which improved fluid circulation is predicted, and bottom-heated, a control resembling traditional bottom-heated OHPs. Results showed stronger circulation, reduced temperature differences, and lower startup thresholds in most cases. The side-heated orientation achieved higher maximum heat loads at a fill ratio of 0.5, although the maximum load decreased at a fill ratio of 0.7. Notably, the helix-shaped OHP attained effective thermal conductivity values over 9,000 WmK in multiple test cases and a maximum heat transport of 676 W. Additional parameters were explored, including heat load, fill ratio, condenser temperature, and the presence of noncondensible gases (NCGs). The presence of NCGs increased not only the temperature drop as expected, but also increased the maximum heat transport, indicating potential benefits in certain applications. Elevated condenser temperatures not only decreased the temperature drop, but also reduced maximum heat transport. A previously developed OHP performance model was expanded to evaluate the novel helix-shaped OHP. The model predicted temperature drops during degassed experiments under moderate heat loads reasonably well. However, most data points fell outside the model's scope, emphasizing the need to extend it to handle condenser bubble collapse. The expanded analytical models for side-heated helix-shaped OHPs highlighted a different set of restrictions on circulation than traditional, bottom-heated OHPs, which likely explains the superior performance of the helix-shaped OHP in its intended orientation.
    • Download: (3.095Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Study of a Novel Helix-Shaped Oscillating Heat Pipe and Design Parameters for Flow Stabilization

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4303093
    Collections
    • ASME Journal of Heat and Mass Transfer

    Show full item record

    contributor authorPawlick, Max
    contributor authorPeterson, G. P.
    date accessioned2024-12-24T18:59:10Z
    date available2024-12-24T18:59:10Z
    date copyright6/6/2024 12:00:00 AM
    date issued2024
    identifier issn2832-8450
    identifier otherht_146_10_103001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4303093
    description abstractA novel helix-shaped oscillating heat pipe (OHP) designed for enhanced heat transfer in thermal management and heat recovery systems was studied experimentally. Two orientations were explored: side-heated, which is the intended orientation in which improved fluid circulation is predicted, and bottom-heated, a control resembling traditional bottom-heated OHPs. Results showed stronger circulation, reduced temperature differences, and lower startup thresholds in most cases. The side-heated orientation achieved higher maximum heat loads at a fill ratio of 0.5, although the maximum load decreased at a fill ratio of 0.7. Notably, the helix-shaped OHP attained effective thermal conductivity values over 9,000 WmK in multiple test cases and a maximum heat transport of 676 W. Additional parameters were explored, including heat load, fill ratio, condenser temperature, and the presence of noncondensible gases (NCGs). The presence of NCGs increased not only the temperature drop as expected, but also increased the maximum heat transport, indicating potential benefits in certain applications. Elevated condenser temperatures not only decreased the temperature drop, but also reduced maximum heat transport. A previously developed OHP performance model was expanded to evaluate the novel helix-shaped OHP. The model predicted temperature drops during degassed experiments under moderate heat loads reasonably well. However, most data points fell outside the model's scope, emphasizing the need to extend it to handle condenser bubble collapse. The expanded analytical models for side-heated helix-shaped OHPs highlighted a different set of restrictions on circulation than traditional, bottom-heated OHPs, which likely explains the superior performance of the helix-shaped OHP in its intended orientation.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Study of a Novel Helix-Shaped Oscillating Heat Pipe and Design Parameters for Flow Stabilization
    typeJournal Paper
    journal volume146
    journal issue10
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4065576
    journal fristpage103001-1
    journal lastpage103001-10
    page10
    treeASME Journal of Heat and Mass Transfer:;2024:;volume( 146 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian