Show simple item record

contributor authorDas, Supreeti
contributor authorAgarwal, Pritwish
contributor authorSahota, Lovedeep
contributor authorMeena, Yogesh Kumar
contributor authorSingh, Manoj
contributor authorGill, Baljit Singh
date accessioned2024-04-24T22:46:08Z
date available2024-04-24T22:46:08Z
date copyright3/18/2024 12:00:00 AM
date issued2024
identifier issn0199-6231
identifier othersol_146_4_041008.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295839
description abstractClean drinking water and electricity production utilizing non-conventional sources of energy is the global demand for sustainable development. Ultrafast heat transfer fluids have delivered impressive results in photovoltaic (PV)-integrated solar thermal systems, in recent times. Efforts have been made for the productivity and electricity augmentation of solar still equipped with helically coilled heat exchanger and coupled with different integrations, viz., (a) partially covered N-photovoltaic thermal compound parabolic concentrator (N-PVT-CPC), (b) partially covered N-photovoltaic thermal flat plate collector (N-PVT-FPC), (c) N-FPC-CPC, and (d) N-flat plate collector (N-FPC). System design has also been modified by adding a roof-top semi-transparent PV module and built-in passive copper condenser (circulation mode), and effect of carbon quantum dots (CQDs) water-based nanofluids, nanoparticles volume concentration, and packing factor (βc) of the PV module has been studied by developing generalized thermal modeling of the system (special cases). Overall, 41.1%, 21.52%, 22.01%, and 10.01% rise in evaporative HTCs is observed in FPC-CPC, PVT-CPC, FPC, and PVT-FPC integrations, respectively. Thermal exergy is found to be higher for FPC-CPC integration, and it follows the enhancement order as FPC-CPC (max-0.147 kW) > PVT-CPC (0.088 kW) > FPC (0.038 kW) > PVT-FPC (0.028 kW). In reference to the base fluid, significant enhancement in the daily productivity is observed for FPC-CPC (10.9%) and PVT-CPC (5.16%) integrations using CQD-NPs. The production cost of potable water has also been estimated for all the cases for n = 30 and n = 50 years life span and i = 4% and 8% interest rates, and it is found to be the lowest (0.014 $/L) for FPC-CPC integration using CQD-NPs (n = 30 years, i = 4%).
publisherThe American Society of Mechanical Engineers (ASME)
titleEconomic and Performance Analysis of Modified Solar Distillation System Coupling Different Integrations Using Carbon Quantum Dot Nanoparticles: Generalized Thermal Model
typeJournal Paper
journal volume146
journal issue4
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4064774
journal fristpage41008-1
journal lastpage41008-20
page20
treeJournal of Solar Energy Engineering:;2024:;volume( 146 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record