Show simple item record

contributor authorFeng, Wei
contributor authorGao, Yu
contributor authorLi, Wei
contributor authorLi, Junye
contributor authorCao, Yanlong
contributor authorLi, Tianwen
contributor authorSherif, S. A.
contributor authorMa, Lianxiang
contributor authorKe, Hanbing
date accessioned2024-04-24T22:45:45Z
date available2024-04-24T22:45:45Z
date copyright11/3/2023 12:00:00 AM
date issued2023
identifier issn0199-6231
identifier othersol_146_3_031004.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295831
description abstractA horizontal smooth copper tube and two enhanced tubes (a dimpled tube and a diamond-shaped tube) with a length of 2 m and an outer diameter of 9.52 mm were studied in a two-phase condensation experiment using R410A and R32 as heat transfer working fluids. The condensation heat transfer performance of different heat transfer tubes at various mass fluxes ranging from 150 to 400 kg/(m2s) and different vapor qualities ranging from 0.8 to 0.2 was studied experimentally. For R410A, the heat transfer coefficients (HTCs) of the dimpled tube and the diamond-shaped tube were found to be 1.39–1.52 times and 1.30–1.35 times higher than those of the smooth tube, respectively. For R32, the HTCs were found to be 1.46–1.59 times higher for the dimpled tube and 1.26–1.35 times higher for the diamond-shaped tube than for the smooth tube. The diamond-shaped tube was found to be effective in directing the flow of the liquid phase and in thinning the liquid film thickness. The dimpled tube was found to promote droplet entrainment and disturbance. Both of those effects contributed to improving the HTCs in the two enhanced tubes investigated. The HTCs of R410A were found to be lower than those of R32 because of the smaller specific heat capacity, smaller latent heat of condensation, and relatively poorer thermal conductivity of R410A. Taking the combined effect of heat transfer and pressure drop into account, a performance enhancement factor (PEF) was computed and was found to range from 0.9 to 1.51. Based on the experimental data collected, a new empirical correlation equation has been proposed with a maximum error band of 10%. Flow pattern maps for the tested tubes have also been generated and are presented in the paper. Both of the two enhanced tubes were found to promote the development of annular flow. The HTCs were found to be highest when the flow pattern was of the annular flow type.
publisherThe American Society of Mechanical Engineers (ASME)
titleCondensation Heat Transfer Experiments of R410A and R32 in Horizontal Smooth and Enhanced Tubes
typeJournal Paper
journal volume146
journal issue3
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.4063855
journal fristpage31004-1
journal lastpage31004-15
page15
treeJournal of Solar Energy Engineering:;2023:;volume( 146 ):;issue: 003
contenttypeFulltext