    Influences of Sediment Particles on Air Vessel Water Hammer Protection Effect in the Long-Distance Water Supply Systems

    Source: Journal of Pressure Vessel Technology:;2023:;volume( 146 ):;issue: 001::page 11401-1
    Author:
    Wang, Yiran
    ,
    Yu, Xiaodong
    ,
    Liu, Jiachun
    ,
    Shi, Lin
    ,
    Zhang, Jian
    DOI: 10.1115/1.4063888
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Long-distance water supply systems are important measures to improve the water resources distribution, and the water hammer protection devices such as air vessels are usually added in the project to ensure the safety and stable operation. However, the sediment particles are always ignored in the design. Hence, a numerical model and program were established for sediment laden water hammer based on the method of characteristics (MOC). Using the proposed model, the water hammer protection influences of sediment particles parameters are simulated for the same pipeline system of a water supply project. The result shows that the resistance loss of sediment-laden water in pipelines is larger than that of water, and the initial head of pump needed to be increased to ensure the water levels of downstream reservoirs are consistent. After power failure and pump stopping, the negative pressure wave of sediment-laden water is 2.97 m higher than that of water, and the theoretical minimum internal pressure along pipelines is 7.8 m lower. With the same air vessel protection, the lowest minimum internal pressure heads along pipelines decrease with the increase of quantities of sediment, while the results show no obvious influence by changes of median particle diameters. The lowest absolute pressure of pipeline could reach −0.69 m under the condition of 50 kg/m3 quantity of sediment and 0.05 mm median particle diameter. The relevant research results are of great significance sediment-laden water hammer numerical simulation and water hammer protection design.
    • Download: (1.882Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Influences of Sediment Particles on Air Vessel Water Hammer Protection Effect in the Long-Distance Water Supply Systems

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295795
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorWang, Yiran
    contributor authorYu, Xiaodong
    contributor authorLiu, Jiachun
    contributor authorShi, Lin
    contributor authorZhang, Jian
    date accessioned2024-04-24T22:44:45Z
    date available2024-04-24T22:44:45Z
    date copyright11/10/2023 12:00:00 AM
    date issued2023
    identifier issn0094-9930
    identifier otherpvt_146_01_011401.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295795
    description abstractLong-distance water supply systems are important measures to improve the water resources distribution, and the water hammer protection devices such as air vessels are usually added in the project to ensure the safety and stable operation. However, the sediment particles are always ignored in the design. Hence, a numerical model and program were established for sediment laden water hammer based on the method of characteristics (MOC). Using the proposed model, the water hammer protection influences of sediment particles parameters are simulated for the same pipeline system of a water supply project. The result shows that the resistance loss of sediment-laden water in pipelines is larger than that of water, and the initial head of pump needed to be increased to ensure the water levels of downstream reservoirs are consistent. After power failure and pump stopping, the negative pressure wave of sediment-laden water is 2.97 m higher than that of water, and the theoretical minimum internal pressure along pipelines is 7.8 m lower. With the same air vessel protection, the lowest minimum internal pressure heads along pipelines decrease with the increase of quantities of sediment, while the results show no obvious influence by changes of median particle diameters. The lowest absolute pressure of pipeline could reach −0.69 m under the condition of 50 kg/m3 quantity of sediment and 0.05 mm median particle diameter. The relevant research results are of great significance sediment-laden water hammer numerical simulation and water hammer protection design.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInfluences of Sediment Particles on Air Vessel Water Hammer Protection Effect in the Long-Distance Water Supply Systems
    typeJournal Paper
    journal volume146
    journal issue1
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.4063888
    journal fristpage11401-1
    journal lastpage11401-8
    page8
    treeJournal of Pressure Vessel Technology:;2023:;volume( 146 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian