    Computational Pulsatile Flow and Efficiency Analysis of Biocompatible Microfluidic Artificial Lungs for Different Fiber Configurations

    Source: Journal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 008::page 81002-1
    Author:
    Asiltürk, Ahmet Yusuf
    ,
    Atalık, Kunt
    DOI: 10.1115/1.4064793
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Average-sized microfluidic artificial lungs consisting of rows and columns of fiber bundles with different column to row aspect ratios (AR) are numerically analyzed for flow characteristics, maximum gas transfer performance, minimum pressure drop, and proper wall shear stress (WSS) values in terms of biocompatibility. The flow is fully laminar and assumed to be incompressible and Newtonian. The transport analysis is performed using a combined convection-diffusion model, and the numerical simulations are carried out with the finite element method. The inlet volumetric flow is modeled as a sinusoidal wave function to simulate the cardiac cycle and its effect on the device performance. The model is first validated with experimental studies in steady-state condition and compared with existing correlations for transient conditions. Then, the validated model is used for a parametric study in both steady and pulsatile flow conditions. The results show that increasing the aspect ratio in fiber configuration leads to converging gas transfer, higher pressure drop, and higher WSS. While determining the optimum configuration, the acceptable shear stress levels play a decisive role to ensure biocompatibility. Also, it is observed that the steady analysis underestimates the gas transfer for higher aspect ratios.
    • Download: (3.120Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Computational Pulsatile Flow and Efficiency Analysis of Biocompatible Microfluidic Artificial Lungs for Different Fiber Configurations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295719
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAsiltürk, Ahmet Yusuf
    contributor authorAtalık, Kunt
    date accessioned2024-04-24T22:42:21Z
    date available2024-04-24T22:42:21Z
    date copyright3/21/2024 12:00:00 AM
    date issued2024
    identifier issn0148-0731
    identifier otherbio_146_08_081002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295719
    description abstractAverage-sized microfluidic artificial lungs consisting of rows and columns of fiber bundles with different column to row aspect ratios (AR) are numerically analyzed for flow characteristics, maximum gas transfer performance, minimum pressure drop, and proper wall shear stress (WSS) values in terms of biocompatibility. The flow is fully laminar and assumed to be incompressible and Newtonian. The transport analysis is performed using a combined convection-diffusion model, and the numerical simulations are carried out with the finite element method. The inlet volumetric flow is modeled as a sinusoidal wave function to simulate the cardiac cycle and its effect on the device performance. The model is first validated with experimental studies in steady-state condition and compared with existing correlations for transient conditions. Then, the validated model is used for a parametric study in both steady and pulsatile flow conditions. The results show that increasing the aspect ratio in fiber configuration leads to converging gas transfer, higher pressure drop, and higher WSS. While determining the optimum configuration, the acceptable shear stress levels play a decisive role to ensure biocompatibility. Also, it is observed that the steady analysis underestimates the gas transfer for higher aspect ratios.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComputational Pulsatile Flow and Efficiency Analysis of Biocompatible Microfluidic Artificial Lungs for Different Fiber Configurations
    typeJournal Paper
    journal volume146
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4064793
    journal fristpage81002-1
    journal lastpage81002-10
    page10
    treeJournal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian