    Aerodynamic Analysis of Low-Pressure Axial Fans Installed in Parallel

    Source: Journal of Fluids Engineering:;2024:;volume( 146 ):;issue: 005::page 51204-1
    Author:
    Ghosh, Debarshee
    ,
    Andersson, Niklas
    ,
    Etemad, Sassan
    DOI: 10.1115/1.4064292
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Ducted rotor-only low-pressure axial fans play an integral role in automotive thermal management. The tightly packed under-hood region and down-stream heat-exchanger shape limit the fan diameter. In order to circumvent this limitation, multiple cooling fans of small diameters are tightly packaged and placed in parallel. Currently, there is limited scientific work, that study the aerodynamics of low-pressure axial fans when installed in parallel. This work aims to quantify the aerodynamic performance and the flow-field as a result of installing low-pressure axial fans in parallel through computational fluid dynamics (CFD). Publicly available experimental data from Friedrich-Alexander University is used for the validation of the numerical setup. Three-dimensional, full-annulus, unsteady Reynolds-averaged Navier‐Stokes (URANS) analysis has been performed for both a single-fan and two-fans installed in parallel and their respective aerodynamic performance has been compared for the operation condition identified as the best efficiency point in experiments. Only small differences are observed in the overall aerodynamic performance of the two-fans in parallel compared to a single-fan. A circumferential nonuniformity in the form of a local high-pressure zone at the inlet of the fan is observed when the two-fans are placed in parallel. The resulting circumferential nonuniformity is quantified, both in space and time. A strong correlation is found between the pressure fields of the two-fans installed in parallel.
    • Download: (4.617Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Aerodynamic Analysis of Low-Pressure Axial Fans Installed in Parallel

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4295126
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorGhosh, Debarshee
    contributor authorAndersson, Niklas
    contributor authorEtemad, Sassan
    date accessioned2024-04-24T22:23:14Z
    date available2024-04-24T22:23:14Z
    date copyright1/24/2024 12:00:00 AM
    date issued2024
    identifier issn0098-2202
    identifier otherfe_146_05_051204.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295126
    description abstractDucted rotor-only low-pressure axial fans play an integral role in automotive thermal management. The tightly packed under-hood region and down-stream heat-exchanger shape limit the fan diameter. In order to circumvent this limitation, multiple cooling fans of small diameters are tightly packaged and placed in parallel. Currently, there is limited scientific work, that study the aerodynamics of low-pressure axial fans when installed in parallel. This work aims to quantify the aerodynamic performance and the flow-field as a result of installing low-pressure axial fans in parallel through computational fluid dynamics (CFD). Publicly available experimental data from Friedrich-Alexander University is used for the validation of the numerical setup. Three-dimensional, full-annulus, unsteady Reynolds-averaged Navier‐Stokes (URANS) analysis has been performed for both a single-fan and two-fans installed in parallel and their respective aerodynamic performance has been compared for the operation condition identified as the best efficiency point in experiments. Only small differences are observed in the overall aerodynamic performance of the two-fans in parallel compared to a single-fan. A circumferential nonuniformity in the form of a local high-pressure zone at the inlet of the fan is observed when the two-fans are placed in parallel. The resulting circumferential nonuniformity is quantified, both in space and time. A strong correlation is found between the pressure fields of the two-fans installed in parallel.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAerodynamic Analysis of Low-Pressure Axial Fans Installed in Parallel
    typeJournal Paper
    journal volume146
    journal issue5
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4064292
    journal fristpage51204-1
    journal lastpage51204-10
    page10
    treeJournal of Fluids Engineering:;2024:;volume( 146 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian