Show simple item record

contributor authorArora, Amit
contributor authorSubbarao, P. M. V.
date accessioned2023-11-29T19:43:18Z
date available2023-11-29T19:43:18Z
date copyright8/16/2023 12:00:00 AM
date issued8/16/2023 12:00:00 AM
date issued2023-08-16
identifier issn1948-5085
identifier othertsea_15_11_111009.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294980
description abstractEnhancing gas-side thermal conductance is essential for the compact sizing of finned-tube heat exchangers, and this study attempts it by integrating vortex generators. The orientation of the vortex generators, which is defined by its attack angle, has a strong bearing on the degree of augmentation. As the energy efficiency keeps varying with the attack angle, the thrust of this investigation is to identify the best attack angle(s) for the stipulated task. For that purpose, four distinct attack angles (i.e., 15 deg, 30 deg, 45 deg and 60 deg), representing the entire effective range, are considered. Since spatial positioning of the generators too has a strong bearing on energy efficiency, therefore, its effect is duly accounted for a comprehensive investigation. For the selection of optimal designs, regression-based phenomenological models are used as they apply thermo-hydraulic trade-offs. After determining the best angle(s), a study is carried out to evaluate their robustness under varying operating conditions. Although phenomenological models are adequate for design optimization, they do not describe the physics of thermo-hydraulic enhancement. Therefore, a study explaining the bearing of design modifications on the local characteristics too is carried out. Additionally, a study discussing the effect of generators’ attack angle on heat transfer over the wake-affected surfaces, which has a predominant existence in baseline flows, is reported. It has been found that thermal augmentation over the said surfaces is the key to compact sizing of the system. For a selected wake-region deployment, the highest relative Colburn j-factor corresponding to wake-affected fin equals 3.07 at the specified Reynolds number.
publisherThe American Society of Mechanical Engineers (ASME)
titleAttack Angle Parametrization for Capacity Augmentation and Wake Management by Vortex Generators in Finned Compact Heat Exchangers
typeJournal Paper
journal volume15
journal issue11
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4063046
journal fristpage111009-1
journal lastpage111009-12
page12
treeJournal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record