    Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response

    Source: Journal of Medical Devices:;2023:;volume( 017 ):;issue: 001::page 11009-1
    Author:
    Pena, Mirle
    ,
    Neu, Dylan T.
    ,
    Feng, H. Amy
    ,
    Hammond, Duane R.
    ,
    Mead, Kenneth R.
    ,
    Banerjee, Rupak K.
    DOI: 10.1115/1.4056694
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Emergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, “Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study,” Lancet Pub. Health, 5(9), pp. e475–e483; Brown et al., 2021, “Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures,” Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.
    • Download: (1.134Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Use of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292423
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorPena, Mirle
    contributor authorNeu, Dylan T.
    contributor authorFeng, H. Amy
    contributor authorHammond, Duane R.
    contributor authorMead, Kenneth R.
    contributor authorBanerjee, Rupak K.
    date accessioned2023-08-16T18:44:46Z
    date available2023-08-16T18:44:46Z
    date copyright1/31/2023 12:00:00 AM
    date issued2023
    identifier issn1932-6181
    identifier othermed_017_01_011009.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292423
    description abstractEmergency medical service (EMS) providers have a higher potential exposure to infectious agents than the general public (Nguyen et al., 2020, “Risk of COVID-19 Among Frontline Healthcare Workers and the General Community: A Prospective Cohort Study,” Lancet Pub. Health, 5(9), pp. e475–e483; Brown et al., 2021, “Risk for Acquiring Coronavirus Disease Illness Among Emergency Medical Service Personnel Exposed to Aerosol-Generating Procedures,” Emer. Infect. Disease J., 27(9), p. 2340). The use of protective equipment may reduce, but does not eliminate their risk of becoming infected as a result of these exposures. Prehospital environments have a high risk of disease transmission exposing EMS providers to bioaerosols and droplets from infectious patients. Field intubation procedures may be performed causing the generation of bioaerosols, thereby increasing the exposure of EMS workers to pathogens. Additionally, ambulances have a reduced volume compared to a hospital treatment space, often without an air filtration system, and no control mechanism to reduce exposure. This study evaluated a containment plus filtration intervention for reducing aerosol concentrations in the patient module of an ambulance. Aerosol concentration measurements were taken in an unoccupied research ambulance at National Institute for Occupational Safety and Health (NIOSH) Cincinnati using a tracer aerosol and optical particle counters (OPCs). The evaluated filtration intervention was a containment pod with a high efficiency particulate air (HEPA)-filtered extraction system that was developed and tested based on its ability to contain, capture, and remove aerosols during the intubation procedure. Three conditions were tested (1) baseline (without intervention), (2) containment pod with HEPA-1, and (3) containment pod with HEPA-2. The containment pod with HEPA-filtered extraction intervention provided containment of 95% of the total generated particle concentration during aerosol generation relative to the baseline condition, followed by rapid air cleaning within the containment pod. This intervention can help reduce aerosol concentrations within ambulance patient modules while performing aerosol-generating procedures.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleUse of a Negative Pressure Containment Pod Within Ambulance-Workspace During Pandemic Response
    typeJournal Paper
    journal volume17
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4056694
    journal fristpage11009-1
    journal lastpage11009-9
    page9
    treeJournal of Medical Devices:;2023:;volume( 017 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian