    Application of Artificial Neural Network to Nucleic Acid Analysis: Accurate Discrimination for Untypical Real-Time Fluorescence Curves With High Specificity and Sensitivity

    Source: Journal of Medical Devices:;2022:;volume( 017 ):;issue: 001::page 11004-1
    Author:
    Miao, Guijun
    ,
    Jiang, Xiaodan
    ,
    Tu, Yunping
    ,
    Zhang, Lulu
    ,
    Yu, Duli
    ,
    Qian, Shizhi
    ,
    Qiu, Xianbo
    DOI: 10.1115/1.4056150
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: As a division of polymerase chain reaction (PCR), convective PCR (CPCR) is able to achieve highly efficient thermal cycling based on free thermal convection with pseudo-isothermal heating, which could be beneficial to point-of-care (POC) nucleic acid analysis. Similar to traditional PCR or isothermal amplification, due to a couple of issues, e.g., reagent, primer design, reactor, reaction dynamics, amplification status, temperature and heating condition, and other reasons, in some cases of CPCR tests, untypical real-time fluorescence curves with positive or negative tests will show up. Especially, when parts of the characteristics between untypical low-positive and negative tests are mixed together, it is difficult to discriminate between them using traditional cycle threshold (Ct) value method. To handle this issue which may occur in CPCR, traditional PCR or isothermal amplification, as an example, instead of using complicated mathematical modeling and signal processing strategy, an artificial intelligence (AI) classification method with artificial neural network (ANN) modeling is developed to improve the accuracy of nucleic acid detection. It has been proven that both the detection specificity and sensitivity can be significantly improved even with a simple ANN model. It can be estimated that the developed method based on AI modeling can be adopted to solve similar problem with PCR or isothermal amplification methods.
    • Download: (2.380Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Application of Artificial Neural Network to Nucleic Acid Analysis: Accurate Discrimination for Untypical Real-Time Fluorescence Curves With High Specificity and Sensitivity

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292417
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorMiao, Guijun
    contributor authorJiang, Xiaodan
    contributor authorTu, Yunping
    contributor authorZhang, Lulu
    contributor authorYu, Duli
    contributor authorQian, Shizhi
    contributor authorQiu, Xianbo
    date accessioned2023-08-16T18:44:28Z
    date available2023-08-16T18:44:28Z
    date copyright12/12/2022 12:00:00 AM
    date issued2022
    identifier issn1932-6181
    identifier othermed_017_01_011004.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292417
    description abstractAs a division of polymerase chain reaction (PCR), convective PCR (CPCR) is able to achieve highly efficient thermal cycling based on free thermal convection with pseudo-isothermal heating, which could be beneficial to point-of-care (POC) nucleic acid analysis. Similar to traditional PCR or isothermal amplification, due to a couple of issues, e.g., reagent, primer design, reactor, reaction dynamics, amplification status, temperature and heating condition, and other reasons, in some cases of CPCR tests, untypical real-time fluorescence curves with positive or negative tests will show up. Especially, when parts of the characteristics between untypical low-positive and negative tests are mixed together, it is difficult to discriminate between them using traditional cycle threshold (Ct) value method. To handle this issue which may occur in CPCR, traditional PCR or isothermal amplification, as an example, instead of using complicated mathematical modeling and signal processing strategy, an artificial intelligence (AI) classification method with artificial neural network (ANN) modeling is developed to improve the accuracy of nucleic acid detection. It has been proven that both the detection specificity and sensitivity can be significantly improved even with a simple ANN model. It can be estimated that the developed method based on AI modeling can be adopted to solve similar problem with PCR or isothermal amplification methods.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleApplication of Artificial Neural Network to Nucleic Acid Analysis: Accurate Discrimination for Untypical Real-Time Fluorescence Curves With High Specificity and Sensitivity
    typeJournal Paper
    journal volume17
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4056150
    journal fristpage11004-1
    journal lastpage11004-10
    page10
    treeJournal of Medical Devices:;2022:;volume( 017 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian