    Joint Coordinate System Using Functional Axes Achieves Clinically Meaningful Kinematics of the Tibiofemoral Joint as Compared to the International Society of Biomechanics Recommendation

    Source: Journal of Biomechanical Engineering:;2023:;volume( 145 ):;issue: 005::page 51005-1
    Author:
    Pourtabib, Joe
    ,
    Hull, M. L.
    DOI: 10.1115/1.4056654
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Quantification of clinically meaningful tibiofemoral motions requires a joint coordinate system (JCS) with motions free from kinematic crosstalk errors. The objectives were to use a JCS with literature-backed functional axes (FUNC) and a JCS recommended by the International Society of Biomechanics (ISB) to determine tibiofemoral kinematics of the native (i.e., healthy) knee, determine variability associated with each JCS, and determine whether the FUNC JCS significantly reduced kinematic crosstalk errors compared to the ISB JCS. Based on a kinematic model consisting of a three-cylindric joint chain, the FUNC JCS included functional flexion–extension (F–E) and internal-external (I–E) tibial rotation axes. In contrast, the ISB JCS included F–E and I–E axes defined using anatomic landmarks. Single-plane fluoroscopic images in 13 subjects performing a weighted deep knee bend were analyzed. Tibiofemoral kinematics using the FUNC JCS fell within the physiological range of motion in all six degrees-of-freedom. Internal tibial rotation averaged 13 deg for the FUNC JCS versus 10 deg for the ISB JCS and motions in the other four degrees-of-freedom (collectively termed off-axis motions) were minimal as expected based on biomechanical constraints. Off-axis motions for the ISB JCS were significantly greater; maximum valgus rotation was 4 deg and maximum anterior and distraction translations were 9 mm and 25 mm, respectively, which is not physiologic. Variabilities in off-axis motions were significantly greater with the ISB JCS (p < 0.0002). The FUNC JCS achieved clinically meaningful kinematics by significantly reducing kinematic crosstalk errors and is the more suitable coordinate system for quantifying tibiofemoral motions.
    • Download: (1.989Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Joint Coordinate System Using Functional Axes Achieves Clinically Meaningful Kinematics of the Tibiofemoral Joint as Compared to the International Society of Biomechanics Recommendation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292355
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorPourtabib, Joe
    contributor authorHull, M. L.
    date accessioned2023-08-16T18:42:30Z
    date available2023-08-16T18:42:30Z
    date copyright1/23/2023 12:00:00 AM
    date issued2023
    identifier issn0148-0731
    identifier otherbio_145_05_051005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292355
    description abstractQuantification of clinically meaningful tibiofemoral motions requires a joint coordinate system (JCS) with motions free from kinematic crosstalk errors. The objectives were to use a JCS with literature-backed functional axes (FUNC) and a JCS recommended by the International Society of Biomechanics (ISB) to determine tibiofemoral kinematics of the native (i.e., healthy) knee, determine variability associated with each JCS, and determine whether the FUNC JCS significantly reduced kinematic crosstalk errors compared to the ISB JCS. Based on a kinematic model consisting of a three-cylindric joint chain, the FUNC JCS included functional flexion–extension (F–E) and internal-external (I–E) tibial rotation axes. In contrast, the ISB JCS included F–E and I–E axes defined using anatomic landmarks. Single-plane fluoroscopic images in 13 subjects performing a weighted deep knee bend were analyzed. Tibiofemoral kinematics using the FUNC JCS fell within the physiological range of motion in all six degrees-of-freedom. Internal tibial rotation averaged 13 deg for the FUNC JCS versus 10 deg for the ISB JCS and motions in the other four degrees-of-freedom (collectively termed off-axis motions) were minimal as expected based on biomechanical constraints. Off-axis motions for the ISB JCS were significantly greater; maximum valgus rotation was 4 deg and maximum anterior and distraction translations were 9 mm and 25 mm, respectively, which is not physiologic. Variabilities in off-axis motions were significantly greater with the ISB JCS (p < 0.0002). The FUNC JCS achieved clinically meaningful kinematics by significantly reducing kinematic crosstalk errors and is the more suitable coordinate system for quantifying tibiofemoral motions.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleJoint Coordinate System Using Functional Axes Achieves Clinically Meaningful Kinematics of the Tibiofemoral Joint as Compared to the International Society of Biomechanics Recommendation
    typeJournal Paper
    journal volume145
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4056654
    journal fristpage51005-1
    journal lastpage51005-7
    page7
    treeJournal of Biomechanical Engineering:;2023:;volume( 145 ):;issue: 005
    contenttypeFulltext