YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Cadaveric Comparison of the Kinematic and Anatomical Axes and Arthrokinematics of the Metatarsosesamoidal and First Metatarsophalangeal Joints

    Source: Journal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 004::page 44502-1
    Author:
    Thorhauer, Eric
    ,
    French, Mackenzie
    ,
    Kimura, Tadashi
    ,
    Ledoux, William R.
    DOI: 10.1115/1.4056060
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Presently, developments in weightbearing computed tomography and biplanar fluoroscopy technologies offer exciting avenues for investigating normative and pathologic foot function with increasing precision. Still, data quantifying sesamoid bone and proximal phalange motion are currently sparse. To express joint kinematics and compare various clinical cohorts, future studies of first ray motion will necessitate robust coordinate frames that respect the variations in underlying anatomy while also aligning closely with the functional, physiological axes of motion. These activity-dependent functional axes may be represented by a mean helical axis of the joint motion. Our cadaveric study quantified joint kinematics from weightbearing computed tomography scans during simulated toe lift and heel rise tasks. We compared the spatial orientations of the mean finite helical axes of the metatarsosesamoidal and metatarsophalangeal joints to the primary joint axis of two relevant methods for defining metatarsal coordinate frames: inertial axes and fitting of geometric primitives. The resultant kinematics exhibited less crosstalk when using a metatarsal coordinate system based on fitting cylindrical primitives to the bony anatomy compared to using principal component axes. Respective metatarsophalangeal and metatarsosesamoidal arthrokinematic contact paths and instantaneous centers of rotation were similar between activities and agree well with currently published data. This study outlines a methodology for quantitatively assessing the efficacy and utility of various anatomical joint coordinate system definitions. Improvements in our ability to characterize the shape and motion of foot bones in the context of functional tasks will elucidate their biomechanical roles and aid clinicians in refining treatment strategies.
    • Download: (3.116Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Cadaveric Comparison of the Kinematic and Anatomical Axes and Arthrokinematics of the Metatarsosesamoidal and First Metatarsophalangeal Joints

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4292322
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorThorhauer, Eric
    contributor authorFrench, Mackenzie
    contributor authorKimura, Tadashi
    contributor authorLedoux, William R.
    date accessioned2023-08-16T18:41:16Z
    date available2023-08-16T18:41:16Z
    date copyright12/9/2022 12:00:00 AM
    date issued2022
    identifier issn0148-0731
    identifier otherbio_145_04_044502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292322
    description abstractPresently, developments in weightbearing computed tomography and biplanar fluoroscopy technologies offer exciting avenues for investigating normative and pathologic foot function with increasing precision. Still, data quantifying sesamoid bone and proximal phalange motion are currently sparse. To express joint kinematics and compare various clinical cohorts, future studies of first ray motion will necessitate robust coordinate frames that respect the variations in underlying anatomy while also aligning closely with the functional, physiological axes of motion. These activity-dependent functional axes may be represented by a mean helical axis of the joint motion. Our cadaveric study quantified joint kinematics from weightbearing computed tomography scans during simulated toe lift and heel rise tasks. We compared the spatial orientations of the mean finite helical axes of the metatarsosesamoidal and metatarsophalangeal joints to the primary joint axis of two relevant methods for defining metatarsal coordinate frames: inertial axes and fitting of geometric primitives. The resultant kinematics exhibited less crosstalk when using a metatarsal coordinate system based on fitting cylindrical primitives to the bony anatomy compared to using principal component axes. Respective metatarsophalangeal and metatarsosesamoidal arthrokinematic contact paths and instantaneous centers of rotation were similar between activities and agree well with currently published data. This study outlines a methodology for quantitatively assessing the efficacy and utility of various anatomical joint coordinate system definitions. Improvements in our ability to characterize the shape and motion of foot bones in the context of functional tasks will elucidate their biomechanical roles and aid clinicians in refining treatment strategies.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Cadaveric Comparison of the Kinematic and Anatomical Axes and Arthrokinematics of the Metatarsosesamoidal and First Metatarsophalangeal Joints
    typeJournal Paper
    journal volume145
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4056060
    journal fristpage44502-1
    journal lastpage44502-11
    page11
    treeJournal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian