    Experimental Investigation of Air Cooling With/Out Tab Cooling in Cell and Module Levels for Thermal Uniformity in Battery Packs

    Source: ASME Journal of Heat and Mass Transfer:;2022:;volume( 145 ):;issue: 002::page 22903-1
    Author:
    Gocmen, Sinan
    ,
    Cetkin, Erdal
    DOI: 10.1115/1.4055939
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Catastrophic effects of global warming and environmental pollution are becoming more evident each day, and reduction in fossil fuel consumption is an urgent need. Thus, electric vehicles powered by sustainable energy sources are becoming a major interest. However, there are some challenges such as safety, limited range, long charging times, and battery life which are inhibitory to the adaptation of them. One of the biggest reasons for these challenges is the relationship between battery degradation and temperature which can be eliminated if batteries can be kept at the optimum temperature range. Here, the effects of three distinct (natural convection, forced convection, and tab cooling) methodology were experimentally compared at both the cell and module levels (six serial 7.5 Ah Kokam pouch cells, 1P6S) for thermal management of lithium-ion cells. The experiments were conducted at a discharge rate of 3C with ambient temperatures of 24 °C and 29 °C. The cell-level test results show that the tab cooling yields 32.5% better thermal uniformity in comparison to the other techniques. Furthermore, tab cooling yields better temperature uniformity with and without air convection as the hot spots occurring near the tabs is eliminated. For the module level, the forced air convection method stands out as the best option with a 4.3% temperature deviation between cells and maximum cell temperature of 39 °C. Overall, the results show that a hybrid approach with tab cooling would be beneficial in terms of temperature homogeneity especially in high capacity electric vehicle battery cells.
    • Download: (2.207Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Investigation of Air Cooling With/Out Tab Cooling in Cell and Module Levels for Thermal Uniformity in Battery Packs

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4291934
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorGocmen, Sinan
    contributor authorCetkin, Erdal
    date accessioned2023-08-16T18:25:19Z
    date available2023-08-16T18:25:19Z
    date copyright12/1/2022 12:00:00 AM
    date issued2022
    identifier issn2832-8450
    identifier otherht_145_02_022903.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4291934
    description abstractCatastrophic effects of global warming and environmental pollution are becoming more evident each day, and reduction in fossil fuel consumption is an urgent need. Thus, electric vehicles powered by sustainable energy sources are becoming a major interest. However, there are some challenges such as safety, limited range, long charging times, and battery life which are inhibitory to the adaptation of them. One of the biggest reasons for these challenges is the relationship between battery degradation and temperature which can be eliminated if batteries can be kept at the optimum temperature range. Here, the effects of three distinct (natural convection, forced convection, and tab cooling) methodology were experimentally compared at both the cell and module levels (six serial 7.5 Ah Kokam pouch cells, 1P6S) for thermal management of lithium-ion cells. The experiments were conducted at a discharge rate of 3C with ambient temperatures of 24 °C and 29 °C. The cell-level test results show that the tab cooling yields 32.5% better thermal uniformity in comparison to the other techniques. Furthermore, tab cooling yields better temperature uniformity with and without air convection as the hot spots occurring near the tabs is eliminated. For the module level, the forced air convection method stands out as the best option with a 4.3% temperature deviation between cells and maximum cell temperature of 39 °C. Overall, the results show that a hybrid approach with tab cooling would be beneficial in terms of temperature homogeneity especially in high capacity electric vehicle battery cells.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Investigation of Air Cooling With/Out Tab Cooling in Cell and Module Levels for Thermal Uniformity in Battery Packs
    typeJournal Paper
    journal volume145
    journal issue2
    journal titleASME Journal of Heat and Mass Transfer
    identifier doi10.1115/1.4055939
    journal fristpage22903-1
    journal lastpage22903-10
    page10
    treeASME Journal of Heat and Mass Transfer:;2022:;volume( 145 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian