    Experimental Studies on Seismic Performance of Mechanically Spliced Precast Bridge Columns

    Source: Journal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 011::page 04022102
    Author:
    Mostafa Tazarv
    ,
    Theodore Sjurseth
    ,
    Evan Greeneway
    ,
    Kallan Hart
    ,
    Mathew LaVoy
    ,
    Nadim Wehbe
    DOI: 10.1061/(ASCE)BE.1943-5592.0001948
    Publisher: ASCE
    Abstract: A mechanical bar splice, which is known as a bar coupler, is an alternative to traditional lap splicing to connect bars in reinforced-concrete (RC) structures. Although it is feasible to incorporate mechanical bar splices in bridge bents as a precast detailing to expedite construction, the use of bar couplers in the plastic hinge region of bridge columns is prohibited in current US codes. This ban was mainly because the coupler performance and the effects of couplers on the seismic behavior of columns were not fully understood. Further, the test data regarding the performance of mechanically spliced bridge columns are scarce, and the available data are for columns with different geometries, confinements, and testing procedures. An experimental investigation was performed to systematically determine the seismic performance of mechanically spliced bridge columns and to develop the most comprehensive test database for these columns. Seven half-scale bridge columns were constructed and tested. One column was cast-in-place (CIP) to serve as the reference model and six were precast and incorporating different couplers at the column base with a coupler product per specimen. Two grouted, one threaded, and three hybrid couplers were included. To minimize the effects of other test parameters, all columns had the same geometry, were longitudinally reinforced with steel bars from a single batch, and were tested under the same loading. The test results showed that seismic couplers, which had a consistent failure mode of bar fracture, reduced the precast column displacement capacities from 3% to 45% compared with CIP and the lateral strength of the precast columns was slightly higher than that of CIP. All precast columns that were tested in this study met the current code seismic requirements; therefore, they might be used in any seismic region of the United States. However, only seismic couplers must be utilized in bridge bents. Finally, a simple design method for mechanically spliced bridge columns was evaluated using a database that consisted of 10 specimens and was viable for practice.
    • Download: (3.386Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Studies on Seismic Performance of Mechanically Spliced Precast Bridge Columns

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4289123
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorMostafa Tazarv
    contributor authorTheodore Sjurseth
    contributor authorEvan Greeneway
    contributor authorKallan Hart
    contributor authorMathew LaVoy
    contributor authorNadim Wehbe
    date accessioned2023-04-07T00:29:20Z
    date available2023-04-07T00:29:20Z
    date issued2022/11/01
    identifier other%28ASCE%29BE.1943-5592.0001948.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4289123
    description abstractA mechanical bar splice, which is known as a bar coupler, is an alternative to traditional lap splicing to connect bars in reinforced-concrete (RC) structures. Although it is feasible to incorporate mechanical bar splices in bridge bents as a precast detailing to expedite construction, the use of bar couplers in the plastic hinge region of bridge columns is prohibited in current US codes. This ban was mainly because the coupler performance and the effects of couplers on the seismic behavior of columns were not fully understood. Further, the test data regarding the performance of mechanically spliced bridge columns are scarce, and the available data are for columns with different geometries, confinements, and testing procedures. An experimental investigation was performed to systematically determine the seismic performance of mechanically spliced bridge columns and to develop the most comprehensive test database for these columns. Seven half-scale bridge columns were constructed and tested. One column was cast-in-place (CIP) to serve as the reference model and six were precast and incorporating different couplers at the column base with a coupler product per specimen. Two grouted, one threaded, and three hybrid couplers were included. To minimize the effects of other test parameters, all columns had the same geometry, were longitudinally reinforced with steel bars from a single batch, and were tested under the same loading. The test results showed that seismic couplers, which had a consistent failure mode of bar fracture, reduced the precast column displacement capacities from 3% to 45% compared with CIP and the lateral strength of the precast columns was slightly higher than that of CIP. All precast columns that were tested in this study met the current code seismic requirements; therefore, they might be used in any seismic region of the United States. However, only seismic couplers must be utilized in bridge bents. Finally, a simple design method for mechanically spliced bridge columns was evaluated using a database that consisted of 10 specimens and was viable for practice.
    publisherASCE
    titleExperimental Studies on Seismic Performance of Mechanically Spliced Precast Bridge Columns
    typeJournal Article
    journal volume27
    journal issue11
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001948
    journal fristpage04022102
    journal lastpage04022102_11
    page11
    treeJournal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian