Show simple item record

contributor authorMostafa Tazarv
contributor authorTheodore Sjurseth
contributor authorEvan Greeneway
contributor authorKallan Hart
contributor authorMathew LaVoy
contributor authorNadim Wehbe
date accessioned2023-04-07T00:29:20Z
date available2023-04-07T00:29:20Z
date issued2022/11/01
identifier other%28ASCE%29BE.1943-5592.0001948.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4289123
description abstractA mechanical bar splice, which is known as a bar coupler, is an alternative to traditional lap splicing to connect bars in reinforced-concrete (RC) structures. Although it is feasible to incorporate mechanical bar splices in bridge bents as a precast detailing to expedite construction, the use of bar couplers in the plastic hinge region of bridge columns is prohibited in current US codes. This ban was mainly because the coupler performance and the effects of couplers on the seismic behavior of columns were not fully understood. Further, the test data regarding the performance of mechanically spliced bridge columns are scarce, and the available data are for columns with different geometries, confinements, and testing procedures. An experimental investigation was performed to systematically determine the seismic performance of mechanically spliced bridge columns and to develop the most comprehensive test database for these columns. Seven half-scale bridge columns were constructed and tested. One column was cast-in-place (CIP) to serve as the reference model and six were precast and incorporating different couplers at the column base with a coupler product per specimen. Two grouted, one threaded, and three hybrid couplers were included. To minimize the effects of other test parameters, all columns had the same geometry, were longitudinally reinforced with steel bars from a single batch, and were tested under the same loading. The test results showed that seismic couplers, which had a consistent failure mode of bar fracture, reduced the precast column displacement capacities from 3% to 45% compared with CIP and the lateral strength of the precast columns was slightly higher than that of CIP. All precast columns that were tested in this study met the current code seismic requirements; therefore, they might be used in any seismic region of the United States. However, only seismic couplers must be utilized in bridge bents. Finally, a simple design method for mechanically spliced bridge columns was evaluated using a database that consisted of 10 specimens and was viable for practice.
publisherASCE
titleExperimental Studies on Seismic Performance of Mechanically Spliced Precast Bridge Columns
typeJournal Article
journal volume27
journal issue11
journal titleJournal of Bridge Engineering
identifier doi10.1061/(ASCE)BE.1943-5592.0001948
journal fristpage04022102
journal lastpage04022102_11
page11
treeJournal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record