YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • ASME Journal of Engineering for Sustainable Buildings and Cities
    • View Item
    •   YE&T Library
    • ASME
    • ASME Journal of Engineering for Sustainable Buildings and Cities
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Insulated Glass Unit in High-Glazed Office Buildings in Brazil: Comparative HVAC Consumption Analyses

    Source: ASME Journal of Engineering for Sustainable Buildings and Cities:;2022:;volume( 003 ):;issue: 002::page 21002-1
    Author:
    Pinto
    ,
    Mônica Martins;Westphal
    ,
    Fernando Simon
    DOI: 10.1115/1.4054894
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The insulated glass unit (IGU) system is widely used in the Northern Hemisphere to improve the energy performance of buildings and the thermal comfort of their occupants. However, it has been introduced in the Brazilian market without a proper thermal assessment. Proper glass choice is essential to reduce energy consumption, as the most intense heat exchange occurs through the windows. This research aimed to investigate the influence of IGU use on conditioned office buildings’ energy performance for nine different climates in Brazil, including tropical (Aw, Af, and As) and temperate (Cfa and Cfb) climates. The energy consumption using air-filled IGU was compared to its non-insulated version through computer simulation in EnergyPlus. This sample demonstrated that IGU could generate annual savings in cooling consumption in tropical climates (up to 2.8%) when the outside temperature is constantly higher than the thermostat temperature. However, IGU models resulted in annual cooling consumption up to 9.3% higher in temperate climates by hindering the thermal load dissipation through the façade. The observed sample demonstrated that the IGU could inhibit the dissipation of the indoor thermal load through the façade, which increases energy consumption for cooling compared to models with the same glass but non-insulated. Either in the tropical or the temperate climates analyzed, the use of IGU seems not to be the ideal approach to improve the thermal performance and reduce the cooling energy consumption of highly glazed office buildings in Brazil.
    • Download: (1.489Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Insulated Glass Unit in High-Glazed Office Buildings in Brazil: Comparative HVAC Consumption Analyses

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4287486
    Collections
    • ASME Journal of Engineering for Sustainable Buildings and Cities

    Show full item record

    contributor authorPinto
    contributor authorMônica Martins;Westphal
    contributor authorFernando Simon
    date accessioned2022-08-18T13:07:55Z
    date available2022-08-18T13:07:55Z
    date copyright7/13/2022 12:00:00 AM
    date issued2022
    identifier issn2642-6641
    identifier otherjesbc_3_2_021002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4287486
    description abstractThe insulated glass unit (IGU) system is widely used in the Northern Hemisphere to improve the energy performance of buildings and the thermal comfort of their occupants. However, it has been introduced in the Brazilian market without a proper thermal assessment. Proper glass choice is essential to reduce energy consumption, as the most intense heat exchange occurs through the windows. This research aimed to investigate the influence of IGU use on conditioned office buildings’ energy performance for nine different climates in Brazil, including tropical (Aw, Af, and As) and temperate (Cfa and Cfb) climates. The energy consumption using air-filled IGU was compared to its non-insulated version through computer simulation in EnergyPlus. This sample demonstrated that IGU could generate annual savings in cooling consumption in tropical climates (up to 2.8%) when the outside temperature is constantly higher than the thermostat temperature. However, IGU models resulted in annual cooling consumption up to 9.3% higher in temperate climates by hindering the thermal load dissipation through the façade. The observed sample demonstrated that the IGU could inhibit the dissipation of the indoor thermal load through the façade, which increases energy consumption for cooling compared to models with the same glass but non-insulated. Either in the tropical or the temperate climates analyzed, the use of IGU seems not to be the ideal approach to improve the thermal performance and reduce the cooling energy consumption of highly glazed office buildings in Brazil.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInsulated Glass Unit in High-Glazed Office Buildings in Brazil: Comparative HVAC Consumption Analyses
    typeJournal Paper
    journal volume3
    journal issue2
    journal titleASME Journal of Engineering for Sustainable Buildings and Cities
    identifier doi10.1115/1.4054894
    journal fristpage21002-1
    journal lastpage21002-12
    page12
    treeASME Journal of Engineering for Sustainable Buildings and Cities:;2022:;volume( 003 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian