    Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR

    Source: Journal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 006::page 61008-1
    Author:
    Kovarovic, Brandon
    ,
    Helbock, Ryan
    ,
    Baylous, Kyle
    ,
    Rotman, Oren M.
    ,
    Slepian, Marvin J.
    ,
    Bluestein, Danny
    DOI: 10.1115/1.4054149
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Tissue-based transcatheter aortic valve (AV) replacement (TAVR) devices have been a breakthrough approach for treating aortic valve stenosis. However, with the expansion of TAVR to younger and lower risk patients, issues of long-term durability and thrombosis persist. Recent advances in polymeric valve technology facilitate designing more durable valves with minimal in vivo adverse reactions. We introduce our second-generation polymeric transcatheter aortic valve (TAV) device, designed and optimized to address these issues. We present the optimization process of the device, wherein each aspect of device deployment and functionality was optimized for performance, including unique considerations of polymeric technologies for reducing the volume of the polymer material for lower crimped delivery profiles. The stent frame was optimized to generate larger radial forces with lower material volumes, securing robust deployment and anchoring. The leaflet shape, combined with varying leaflets thickness, was optimized for reducing the flexural cyclic stresses and the valve's hydrodynamics. Our first-generation polymeric device already demonstrated that its hydrodynamic performance meets and exceeds tissue devices for both ISO standard and patient-specific in vitro scenarios. The valve already reached 900 × 106 cycles of accelerated durability testing, equivalent to over 20 years in a patient. The optimization framework and technology led to the second generation of polymeric TAV design- currently undergoing in vitro hydrodynamic testing and following in vivo animal trials. As TAVR use is rapidly expanding, our rigorous bio-engineering optimization methodology and advanced polymer technology serve to establish polymeric TAV technology as a viable alternative to the challenges facing existing tissue-based TAV technology.
    • Download: (7.956Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Visions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4285441
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorKovarovic, Brandon
    contributor authorHelbock, Ryan
    contributor authorBaylous, Kyle
    contributor authorRotman, Oren M.
    contributor authorSlepian, Marvin J.
    contributor authorBluestein, Danny
    date accessioned2022-05-08T09:40:34Z
    date available2022-05-08T09:40:34Z
    date copyright4/6/2022 12:00:00 AM
    date issued2022
    identifier issn0148-0731
    identifier otherbio_144_06_061008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4285441
    description abstractTissue-based transcatheter aortic valve (AV) replacement (TAVR) devices have been a breakthrough approach for treating aortic valve stenosis. However, with the expansion of TAVR to younger and lower risk patients, issues of long-term durability and thrombosis persist. Recent advances in polymeric valve technology facilitate designing more durable valves with minimal in vivo adverse reactions. We introduce our second-generation polymeric transcatheter aortic valve (TAV) device, designed and optimized to address these issues. We present the optimization process of the device, wherein each aspect of device deployment and functionality was optimized for performance, including unique considerations of polymeric technologies for reducing the volume of the polymer material for lower crimped delivery profiles. The stent frame was optimized to generate larger radial forces with lower material volumes, securing robust deployment and anchoring. The leaflet shape, combined with varying leaflets thickness, was optimized for reducing the flexural cyclic stresses and the valve's hydrodynamics. Our first-generation polymeric device already demonstrated that its hydrodynamic performance meets and exceeds tissue devices for both ISO standard and patient-specific in vitro scenarios. The valve already reached 900 × 106 cycles of accelerated durability testing, equivalent to over 20 years in a patient. The optimization framework and technology led to the second generation of polymeric TAV design- currently undergoing in vitro hydrodynamic testing and following in vivo animal trials. As TAVR use is rapidly expanding, our rigorous bio-engineering optimization methodology and advanced polymer technology serve to establish polymeric TAV technology as a viable alternative to the challenges facing existing tissue-based TAV technology.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleVisions of TAVR Future: Development and Optimization of a Second Generation Novel Polymeric TAVR
    typeJournal Paper
    journal volume144
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4054149
    journal fristpage61008-1
    journal lastpage61008-10
    page10
    treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian