    Liquid Droplet Impact Over Hydrophobic Mesh Surfaces and Assessment of Weber Number Dependent Characteristics

    Source: Journal of Fluids Engineering:;2022:;volume( 144 ):;issue: 008::page 81401-1
    Author:
    Abubakar, Abba Abdulhamid
    ,
    Yilbas, Bekir Sami
    ,
    Al-Qahtani, Hussain
    ,
    Mohammed, Anwaruddin Siddiqui
    DOI: 10.1115/1.4053440
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Impacting droplets and droplet ejection from hydrophobic mesh surfaces have interest in biomedicine, heat transfer engineering, and self-cleaning of surfaces. The rate and the size of newborn droplets can vary depending on the droplet fluid properties, Weber number, mesh geometry, and surface wetting states. In this study, impacting water droplets onto hydrophobic mesh surface is investigated and impact properties including, spreading, rebounding, and droplet fluid penetration and ejection rates are examined. Droplet behavior is assessed using high recording facilities and predicted in line with the experiments. The findings reveal that the critical Weber number for droplet fluid penetrating/ejecting from mesh screen mainly depends on the droplet fluid capillary length, and hydrophobic mesh size. The contact time of impacting droplet over mesh surface reduces with increasing droplet Weber number, which opposes the case observed for impacting droplets over flat hydrophobic surfaces. The restitution coefficient attains lower values for impacting droplets over mesh surfaces than that of flat surfaces. The rate and diameter of the ejected droplet from the mesh increases as droplet Weber increases. At the onset of impact, streamline curvature is formed inside droplet fluid, which creates a stagnation zone with radially varying pressure at the droplet fluid mesh interface. This reduces the ejected droplet diameter from mesh cells as mesh cells are located away from the impacting vertical axis.
    • Download: (6.349Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Liquid Droplet Impact Over Hydrophobic Mesh Surfaces and Assessment of Weber Number Dependent Characteristics

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284873
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorAbubakar, Abba Abdulhamid
    contributor authorYilbas, Bekir Sami
    contributor authorAl-Qahtani, Hussain
    contributor authorMohammed, Anwaruddin Siddiqui
    date accessioned2022-05-08T09:13:24Z
    date available2022-05-08T09:13:24Z
    date copyright2/28/2022 12:00:00 AM
    date issued2022
    identifier issn0098-2202
    identifier otherfe_144_08_081401.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284873
    description abstractImpacting droplets and droplet ejection from hydrophobic mesh surfaces have interest in biomedicine, heat transfer engineering, and self-cleaning of surfaces. The rate and the size of newborn droplets can vary depending on the droplet fluid properties, Weber number, mesh geometry, and surface wetting states. In this study, impacting water droplets onto hydrophobic mesh surface is investigated and impact properties including, spreading, rebounding, and droplet fluid penetration and ejection rates are examined. Droplet behavior is assessed using high recording facilities and predicted in line with the experiments. The findings reveal that the critical Weber number for droplet fluid penetrating/ejecting from mesh screen mainly depends on the droplet fluid capillary length, and hydrophobic mesh size. The contact time of impacting droplet over mesh surface reduces with increasing droplet Weber number, which opposes the case observed for impacting droplets over flat hydrophobic surfaces. The restitution coefficient attains lower values for impacting droplets over mesh surfaces than that of flat surfaces. The rate and diameter of the ejected droplet from the mesh increases as droplet Weber increases. At the onset of impact, streamline curvature is formed inside droplet fluid, which creates a stagnation zone with radially varying pressure at the droplet fluid mesh interface. This reduces the ejected droplet diameter from mesh cells as mesh cells are located away from the impacting vertical axis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleLiquid Droplet Impact Over Hydrophobic Mesh Surfaces and Assessment of Weber Number Dependent Characteristics
    typeJournal Paper
    journal volume144
    journal issue8
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4053440
    journal fristpage81401-1
    journal lastpage81401-12
    page12
    treeJournal of Fluids Engineering:;2022:;volume( 144 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian