    Study of the Hydraulic Performances of Two Inducers in Water—CO2 Mixture—Toward Performance Improvement With Suppression of Prerotation

    Source: Journal of Fluids Engineering:;2022:;volume( 144 ):;issue: 004::page 41203-1
    Author:
    Tomov, Petar
    ,
    Pora, Loic
    ,
    Paridaens, Richard
    ,
    Magne, Théodore
    ,
    Kebdani, Mohamed
    ,
    Khelladi, Sofiane
    ,
    Bakir, Farid
    DOI: 10.1115/1.4052951
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The inducers increase the pressure available at the inlet of the impellers of centrifugal pumps. This technological solution may induce instabilities, such as prerotating flow at partial flow rates. The scientific literature offers studies on the cavitation in the inducers, as well as on the associated instabilities. However, studies describing devices that improve the behavior in these unstable regimes are rare. This is particularly true for fluids like aviation fuels or liquids with dissolved gases. In this work we expose, an experimental study for two axial inducers carried out at low flow rates in cavitating and noncavitating regimes in a closed-loop equipped with a transparent test pipe. The working liquid is water with and without dissolved CO2. We employ a camera and a high-speed camera to take the photographs of the dynamics of the cavitation structures. The experimental campaign provided results of head breakdown comparison. The added dissolved CO2 gas at a concentration of 300 mg L–1 does not change the overall inducers' performance in noncavitating regime. The paper presents also the impact of some of inducers' geometrical parameters on their cavitating performance. The authors observed prerotating flow instability, which they tried to decrease by incorporating a grooved ring into the inlet side of the inducers. It is found that prerotating structures are much less developed in the upstream when a grooved ring is employed.
    • Download: (3.537Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Study of the Hydraulic Performances of Two Inducers in Water—CO2 Mixture—Toward Performance Improvement With Suppression of Prerotation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4284794
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorTomov, Petar
    contributor authorPora, Loic
    contributor authorParidaens, Richard
    contributor authorMagne, Théodore
    contributor authorKebdani, Mohamed
    contributor authorKhelladi, Sofiane
    contributor authorBakir, Farid
    date accessioned2022-05-08T09:09:38Z
    date available2022-05-08T09:09:38Z
    date copyright2/7/2022 12:00:00 AM
    date issued2022
    identifier issn0098-2202
    identifier otherfe_144_04_041203.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4284794
    description abstractThe inducers increase the pressure available at the inlet of the impellers of centrifugal pumps. This technological solution may induce instabilities, such as prerotating flow at partial flow rates. The scientific literature offers studies on the cavitation in the inducers, as well as on the associated instabilities. However, studies describing devices that improve the behavior in these unstable regimes are rare. This is particularly true for fluids like aviation fuels or liquids with dissolved gases. In this work we expose, an experimental study for two axial inducers carried out at low flow rates in cavitating and noncavitating regimes in a closed-loop equipped with a transparent test pipe. The working liquid is water with and without dissolved CO2. We employ a camera and a high-speed camera to take the photographs of the dynamics of the cavitation structures. The experimental campaign provided results of head breakdown comparison. The added dissolved CO2 gas at a concentration of 300 mg L–1 does not change the overall inducers' performance in noncavitating regime. The paper presents also the impact of some of inducers' geometrical parameters on their cavitating performance. The authors observed prerotating flow instability, which they tried to decrease by incorporating a grooved ring into the inlet side of the inducers. It is found that prerotating structures are much less developed in the upstream when a grooved ring is employed.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleStudy of the Hydraulic Performances of Two Inducers in Water—CO2 Mixture—Toward Performance Improvement With Suppression of Prerotation
    typeJournal Paper
    journal volume144
    journal issue4
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4052951
    journal fristpage41203-1
    journal lastpage41203-11
    page11
    treeJournal of Fluids Engineering:;2022:;volume( 144 ):;issue: 004
    contenttypeFulltext