YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Combination of Morphological and Hemodynamic Parameters for Assessing the Rupture Risk of Intracranial Aneurysms: A Retrospective Study on Mirror Middle Cerebral Artery Aneurysms

    Source: Journal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 008::page 81006-1
    Author:
    Xin, Shangzhe
    ,
    Chen, Yongchun
    ,
    Zhao, Bing
    ,
    Liang, Fuyou
    DOI: 10.1115/1.4053793
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Discordant findings were frequently reported by studies dedicated to exploring the association of morphological/hemodynamic factors with the rupture of intracranial aneurysms (IAs), probably owing to insufficient control of confounding factors. In this study, we aimed to minimize the influences of confounding factors by focusing IAs of interest on mirror aneurysms and, meanwhile, modeling IAs together with the cerebral arterial network to improve the physiological fidelity of hemodynamic simulation. Fifty-two mirror aneurysms located at the middle cerebral artery (MCA) in 26 patients were retrospectively investigated. Numerical tests performed on two randomly selected patients demonstrated that over truncation of cerebral arteries proximal to the MCA during image-based model reconstruction led to uncertain changes in computed values of intra-aneurysmal hemodynamic parameters, which justified the minimal truncation strategy adopted in our study. Five morphological parameters (i.e., volume (V), height (H), dome area (DA), nonsphericity index (NSI), and size ratio (SR)) and two hemodynamic parameters (i.e., peak wall shear stress (WSS) (peakWSS), and pressure loss coefficient (PLc)) were found to differ significantly between the ruptured and unruptured aneurysms and proved by receiver operating characteristic (ROC) analysis to have potential value for differentiating the rupture status of aneurysm with the areas under curve (AUCs) ranging from 0.681 to 0.763. Integrating V, SR, peakWSS, and PLc or some of them into regression models considerably improved the classification of aneurysms, elevating AUC up to 0.864, which indicates that morphological and hemodynamic parameters have complementary roles in assessing the risk of aneurysm rupture.
    • Download: (2.769Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Combination of Morphological and Hemodynamic Parameters for Assessing the Rupture Risk of Intracranial Aneurysms: A Retrospective Study on Mirror Middle Cerebral Artery Aneurysms

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283992
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorXin, Shangzhe
    contributor authorChen, Yongchun
    contributor authorZhao, Bing
    contributor authorLiang, Fuyou
    date accessioned2022-05-08T08:29:31Z
    date available2022-05-08T08:29:31Z
    date copyright3/9/2022 12:00:00 AM
    date issued2022
    identifier issn0148-0731
    identifier otherbio_144_08_081006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283992
    description abstractDiscordant findings were frequently reported by studies dedicated to exploring the association of morphological/hemodynamic factors with the rupture of intracranial aneurysms (IAs), probably owing to insufficient control of confounding factors. In this study, we aimed to minimize the influences of confounding factors by focusing IAs of interest on mirror aneurysms and, meanwhile, modeling IAs together with the cerebral arterial network to improve the physiological fidelity of hemodynamic simulation. Fifty-two mirror aneurysms located at the middle cerebral artery (MCA) in 26 patients were retrospectively investigated. Numerical tests performed on two randomly selected patients demonstrated that over truncation of cerebral arteries proximal to the MCA during image-based model reconstruction led to uncertain changes in computed values of intra-aneurysmal hemodynamic parameters, which justified the minimal truncation strategy adopted in our study. Five morphological parameters (i.e., volume (V), height (H), dome area (DA), nonsphericity index (NSI), and size ratio (SR)) and two hemodynamic parameters (i.e., peak wall shear stress (WSS) (peakWSS), and pressure loss coefficient (PLc)) were found to differ significantly between the ruptured and unruptured aneurysms and proved by receiver operating characteristic (ROC) analysis to have potential value for differentiating the rupture status of aneurysm with the areas under curve (AUCs) ranging from 0.681 to 0.763. Integrating V, SR, peakWSS, and PLc or some of them into regression models considerably improved the classification of aneurysms, elevating AUC up to 0.864, which indicates that morphological and hemodynamic parameters have complementary roles in assessing the risk of aneurysm rupture.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCombination of Morphological and Hemodynamic Parameters for Assessing the Rupture Risk of Intracranial Aneurysms: A Retrospective Study on Mirror Middle Cerebral Artery Aneurysms
    typeJournal Paper
    journal volume144
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4053793
    journal fristpage81006-1
    journal lastpage81006-11
    page11
    treeJournal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian