    Centrifuge Modeling of Shallow Foundation Lateral Disconnection to Reduce Seismic Vulnerability

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 002::page 04021187
    Author:
    Fausto Somma
    ,
    Emilio Bilotta
    ,
    Alessandro Flora
    ,
    Giulia M. B. Viggiani
    DOI: 10.1061/(ASCE)GT.1943-5606.0002746
    Publisher: ASCE
    Abstract: An innovative yet extremely simple approach to reduce the seismic vulnerability of existing buildings on shallow foundations is to remove the lateral contact between the embedded foundation and the surrounding soil. This paper compares the dynamic response of two identical one-degree-of-freedom reduced-scale model sway frames tested in a geotechnical centrifuge. One of the models was founded on fully embedded shallow strip footings, whereas the foundations of the other were disconnected from the soil laterally. Both models were constructed in dry medium density sand whose strength and small strain shear stiffness profiles were obtained by cone penetration and air hammer tests carried out in flight. Various tools were used to monitor the displacements and accelerations both in the structure and in the soil, including micro-electro-mechanical systems (MEMS) accelerometers, piezoelectric accelerometers, LVDTs, and a high-frequency camera. The experimental results demonstrate that the lateral disconnection of the foundation from the adjacent soil significantly reduces the foundation translational and rotational stiffness, which results in a larger predominant period of the structure and a reduction of the absolute floor accelerations obtained for different sinusoidal input signals. The lateral disconnection also mitigates floor drift and story shear forces. The trade-off is the lower radiative damping observed for the laterally disconnected foundation, which results in a larger number of post-earthquake oscillations of the structure.
    • Download: (4.663Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Centrifuge Modeling of Shallow Foundation Lateral Disconnection to Reduce Seismic Vulnerability

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283583
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorFausto Somma
    contributor authorEmilio Bilotta
    contributor authorAlessandro Flora
    contributor authorGiulia M. B. Viggiani
    date accessioned2022-05-07T21:19:26Z
    date available2022-05-07T21:19:26Z
    date issued2021-12-08
    identifier other(ASCE)GT.1943-5606.0002746.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283583
    description abstractAn innovative yet extremely simple approach to reduce the seismic vulnerability of existing buildings on shallow foundations is to remove the lateral contact between the embedded foundation and the surrounding soil. This paper compares the dynamic response of two identical one-degree-of-freedom reduced-scale model sway frames tested in a geotechnical centrifuge. One of the models was founded on fully embedded shallow strip footings, whereas the foundations of the other were disconnected from the soil laterally. Both models were constructed in dry medium density sand whose strength and small strain shear stiffness profiles were obtained by cone penetration and air hammer tests carried out in flight. Various tools were used to monitor the displacements and accelerations both in the structure and in the soil, including micro-electro-mechanical systems (MEMS) accelerometers, piezoelectric accelerometers, LVDTs, and a high-frequency camera. The experimental results demonstrate that the lateral disconnection of the foundation from the adjacent soil significantly reduces the foundation translational and rotational stiffness, which results in a larger predominant period of the structure and a reduction of the absolute floor accelerations obtained for different sinusoidal input signals. The lateral disconnection also mitigates floor drift and story shear forces. The trade-off is the lower radiative damping observed for the laterally disconnected foundation, which results in a larger number of post-earthquake oscillations of the structure.
    publisherASCE
    titleCentrifuge Modeling of Shallow Foundation Lateral Disconnection to Reduce Seismic Vulnerability
    typeJournal Paper
    journal volume148
    journal issue2
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0002746
    journal fristpage04021187
    journal lastpage04021187-16
    page16
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian