    Load and Resistance Factor Design for Serviceability Limit State of Laterally Loaded Drilled Shafts for Transmission Line Structures in Sands

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 001::page 04021166
    Author:
    Garam Kim
    ,
    Junhwan Lee
    DOI: 10.1061/(ASCE)GT.1943-5606.0002711
    Publisher: ASCE
    Abstract: Load and resistance factor design (LRFD) for serviceability limit state (SLS) of laterally loaded drilled shafts was explored for transmission line structures in sand, and the SLS resistance factor (RF) was proposed. Statistical characteristics of various load components, including transverse tension load (TTL), wind-on-structure load (WSL), and wind-on-conductor load (WCL), were considered and assessed. A database was established and adopted to calibrate RF for SLS of laterally loaded drilled shafts in sands. The hyperbolic model was introduced to quantify uncertainties in the lateral load–displacement curves for drilled shafts and adopted to determine the allowable load capacity. A Monte Carlo simulation was performed to calibrate RF for SLS. The effects of target reliability index (βT), allowable displacement (ya), ice thickness on conductor (Iz), and various load ratios were all considered in the RF calibration. The values of RF for SLS varied from 0.19 to 0.94 for βT in the range of 1.5–3.5. Equivalent factors of safety (FSeq) were obtained for the proposed RFs to evaluate and compare the safety margin of SLS to that of current design practice.
    • Download: (2.615Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Load and Resistance Factor Design for Serviceability Limit State of Laterally Loaded Drilled Shafts for Transmission Line Structures in Sands

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4283550
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorGaram Kim
    contributor authorJunhwan Lee
    date accessioned2022-05-07T21:17:41Z
    date available2022-05-07T21:17:41Z
    date issued2021-10-19
    identifier other(ASCE)GT.1943-5606.0002711.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283550
    description abstractLoad and resistance factor design (LRFD) for serviceability limit state (SLS) of laterally loaded drilled shafts was explored for transmission line structures in sand, and the SLS resistance factor (RF) was proposed. Statistical characteristics of various load components, including transverse tension load (TTL), wind-on-structure load (WSL), and wind-on-conductor load (WCL), were considered and assessed. A database was established and adopted to calibrate RF for SLS of laterally loaded drilled shafts in sands. The hyperbolic model was introduced to quantify uncertainties in the lateral load–displacement curves for drilled shafts and adopted to determine the allowable load capacity. A Monte Carlo simulation was performed to calibrate RF for SLS. The effects of target reliability index (βT), allowable displacement (ya), ice thickness on conductor (Iz), and various load ratios were all considered in the RF calibration. The values of RF for SLS varied from 0.19 to 0.94 for βT in the range of 1.5–3.5. Equivalent factors of safety (FSeq) were obtained for the proposed RFs to evaluate and compare the safety margin of SLS to that of current design practice.
    publisherASCE
    titleLoad and Resistance Factor Design for Serviceability Limit State of Laterally Loaded Drilled Shafts for Transmission Line Structures in Sands
    typeJournal Paper
    journal volume148
    journal issue1
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)GT.1943-5606.0002711
    journal fristpage04021166
    journal lastpage04021166-15
    page15
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2021:;Volume ( 148 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian