    Design Optimization of a Novel Multifiring Clip Applicator System for Endoscopic Closure of Large Perforations

    Source: Journal of Medical Devices:;2021:;volume( 015 ):;issue: 003::page 031007-1
    Author:
    Ai, Liaoyuan
    ,
    Song, Chengli
    ,
    Mao, Lin
    ,
    Ge, Shuchen
    ,
    Pan, Zhen
    DOI: 10.1115/1.4051191
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Endoscopic closure has become the first choice for closing iatrogenic perforations. Previously, we reported a self-developed endoscopic multifiring clip applicator (EMFCA) system. In this paper, a new EMFCA system for endoscopic closure of large perforations with a redesigned clip, the less traumatic grasper, and a highly efficient driving system was presented, and its efficacy was evaluated. The behaviors of the new clip and grasper were verified through finite element analysis (FEA). The capability of pushing transmission for the EMFCA system was identified by the proposed model and the validation experiment. Ex-vivo studies were conducted on porcine stomachs to compare the outcomes of the closures. The FEA results showed that the deformation of the clip was safe and smoother, with a maximum stress of 640.0 MPa. The less traumatic grasper could increase the grasping force and avoid trauma by exerting uniform stress along the axis. The capability of pushing transmission was enhanced by the double-nested tendon-sheath actuation system with an efficiency of 0.45–0.48. The mechanical strength, the leakage pressure, and the operating time for the closures with the new EMFCA system and the previous EMFCA system were 6.1 N ± 0.8 N, 37.1 mmHg ± 6.8 mmHg, 7.3 min ± 0.4 min and 5.1 N ± 1.0 N, 27.4 mmHg ± 6.4 mmHg, 11.4 min ±0.8 min, respectively. The new EMFCA system can realize a superior, reliable, and high-efficiency endoscopic closure of large perforations.
    • Download: (1.617Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design Optimization of a Novel Multifiring Clip Applicator System for Endoscopic Closure of Large Perforations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278728
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorAi, Liaoyuan
    contributor authorSong, Chengli
    contributor authorMao, Lin
    contributor authorGe, Shuchen
    contributor authorPan, Zhen
    date accessioned2022-02-06T05:46:25Z
    date available2022-02-06T05:46:25Z
    date copyright6/17/2021 12:00:00 AM
    date issued2021
    identifier issn1932-6181
    identifier othermed_015_03_031007.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278728
    description abstractEndoscopic closure has become the first choice for closing iatrogenic perforations. Previously, we reported a self-developed endoscopic multifiring clip applicator (EMFCA) system. In this paper, a new EMFCA system for endoscopic closure of large perforations with a redesigned clip, the less traumatic grasper, and a highly efficient driving system was presented, and its efficacy was evaluated. The behaviors of the new clip and grasper were verified through finite element analysis (FEA). The capability of pushing transmission for the EMFCA system was identified by the proposed model and the validation experiment. Ex-vivo studies were conducted on porcine stomachs to compare the outcomes of the closures. The FEA results showed that the deformation of the clip was safe and smoother, with a maximum stress of 640.0 MPa. The less traumatic grasper could increase the grasping force and avoid trauma by exerting uniform stress along the axis. The capability of pushing transmission was enhanced by the double-nested tendon-sheath actuation system with an efficiency of 0.45–0.48. The mechanical strength, the leakage pressure, and the operating time for the closures with the new EMFCA system and the previous EMFCA system were 6.1 N ± 0.8 N, 37.1 mmHg ± 6.8 mmHg, 7.3 min ± 0.4 min and 5.1 N ± 1.0 N, 27.4 mmHg ± 6.4 mmHg, 11.4 min ±0.8 min, respectively. The new EMFCA system can realize a superior, reliable, and high-efficiency endoscopic closure of large perforations.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign Optimization of a Novel Multifiring Clip Applicator System for Endoscopic Closure of Large Perforations
    typeJournal Paper
    journal volume15
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4051191
    journal fristpage031007-1
    journal lastpage031007-8
    page8
    treeJournal of Medical Devices:;2021:;volume( 015 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian