    Design of Contact-Aided Compliant Flexure Hinge Mechanism Using Superelastic Nitinol

    Source: Journal of Mechanical Design:;2021:;volume( 143 ):;issue: 011::page 0114501-1
    Author:
    Ping, Zhongyuan
    ,
    Zhang, Tianci
    ,
    Zhang, Chi
    ,
    Liu, Jianbin
    ,
    Zuo, Siyang
    DOI: 10.1115/1.4050750
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents a novel miniature contact-aided compliant mechanism (CCM) that includes flexure hinges and contact-aided structures. This continuum mechanism comprises a nickel–titanium alloy (Nitinol) tube with CCM cut via laser micromachining and actuated using wires bending from −80 deg to +80 deg in four directions. The proposed CCM has the following merits: perfect capacity for deflection around the centroid, a self-backbone, and improved torsional as well as tensile strengths. Further, it is pre-assembled. First, kinematic and static models are used to predict the bending behavior of the mechanism. Thereafter, the maximum strain is evaluated using finite element analysis (FEA) then compared with the static models. Finally, the performances of the mechanism are characterized by experiments. The results validate the proposed models and demonstrate that the torsional and tensile strengths of the proposed CCM increased by more than 100% and 30%, respectively, compared with those of conventional non-CCMs with a similar fatigue life. Moreover, with the integrated forceps and probe, the proposed mechanism can achieve object transfer and square trajectory scanning of the targeted location. These experimental results demonstrate the potential clinical value of the proposed mechanism and provide important insights into the design of long and flexible instruments for endoscopic surgery.
    • Download: (1.286Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design of Contact-Aided Compliant Flexure Hinge Mechanism Using Superelastic Nitinol

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278694
    Collections
    • Journal of Mechanical Design

    Show full item record

    contributor authorPing, Zhongyuan
    contributor authorZhang, Tianci
    contributor authorZhang, Chi
    contributor authorLiu, Jianbin
    contributor authorZuo, Siyang
    date accessioned2022-02-06T05:45:28Z
    date available2022-02-06T05:45:28Z
    date copyright5/28/2021 12:00:00 AM
    date issued2021
    identifier issn1050-0472
    identifier othermd_143_11_114501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278694
    description abstractThis paper presents a novel miniature contact-aided compliant mechanism (CCM) that includes flexure hinges and contact-aided structures. This continuum mechanism comprises a nickel–titanium alloy (Nitinol) tube with CCM cut via laser micromachining and actuated using wires bending from −80 deg to +80 deg in four directions. The proposed CCM has the following merits: perfect capacity for deflection around the centroid, a self-backbone, and improved torsional as well as tensile strengths. Further, it is pre-assembled. First, kinematic and static models are used to predict the bending behavior of the mechanism. Thereafter, the maximum strain is evaluated using finite element analysis (FEA) then compared with the static models. Finally, the performances of the mechanism are characterized by experiments. The results validate the proposed models and demonstrate that the torsional and tensile strengths of the proposed CCM increased by more than 100% and 30%, respectively, compared with those of conventional non-CCMs with a similar fatigue life. Moreover, with the integrated forceps and probe, the proposed mechanism can achieve object transfer and square trajectory scanning of the targeted location. These experimental results demonstrate the potential clinical value of the proposed mechanism and provide important insights into the design of long and flexible instruments for endoscopic surgery.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign of Contact-Aided Compliant Flexure Hinge Mechanism Using Superelastic Nitinol
    typeJournal Paper
    journal volume143
    journal issue11
    journal titleJournal of Mechanical Design
    identifier doi10.1115/1.4050750
    journal fristpage0114501-1
    journal lastpage0114501-9
    page9
    treeJournal of Mechanical Design:;2021:;volume( 143 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian