    Investigation of a Combined Refrigeration and Air Conditioning System Based on Two-Phase Ejector Driven by Exhaust Gases of Natural Gas Fueled Homogeneous Charge Compression Ignition Engine

    Source: Journal of Energy Resources Technology:;2021:;volume( 143 ):;issue: 012::page 0120911-1
    Author:
    Khaliq, Abdul
    ,
    Almohammadi, Bandar A.
    ,
    Alharthi, Mathkar A.
    ,
    Siddiqui, Mohd Asjad
    ,
    Kumar, Rajesh
    DOI: 10.1115/1.4052248
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A natural gas-fueled homogeneous charge compression ignition (HCCI) engine is coupled to an exhaust gas operated turbine driven two-phase ejector cycle to generate power and cooling energy, simultaneously. By establishing a thermodynamic model, the simulation of the proposed system and its parametric analyses are conducted. Energetic and exergetic investigations are carried out to study the role of equivalence ratio, engine speed, condenser temperature, refrigeration evaporator temperature, air-conditioning evaporator temperature, and ejector nozzle efficiency on the thermodynamic performance parameters of the combined cycle. The analysis of two-phase ejector cooling cycle using three working fluids including R717, R290, and R600a is conducted. Results reveal that the thermal efficiency of HCCI engine is increased from 47.44% to 49.94%, and for the R600a operated combined cycle it is increased from 60.05% to 63.26% when the equivalence ratio is promoted from 0.3 to 0.6. Distribution of fuel exergy results show that out of 100% exergy input, in case of R717 operated combined cycle, 139.79 kW (38.72%) is the total exergy output, and 164.21 kW (45.49%) and 57 kW (15.79%) are the values for exergy destruction and exergy losses. It is further shown that change in refrigerant minorly influence the percentages of exergy distribution.
    • Download: (1.504Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Investigation of a Combined Refrigeration and Air Conditioning System Based on Two-Phase Ejector Driven by Exhaust Gases of Natural Gas Fueled Homogeneous Charge Compression Ignition Engine

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4278477
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorKhaliq, Abdul
    contributor authorAlmohammadi, Bandar A.
    contributor authorAlharthi, Mathkar A.
    contributor authorSiddiqui, Mohd Asjad
    contributor authorKumar, Rajesh
    date accessioned2022-02-06T05:39:06Z
    date available2022-02-06T05:39:06Z
    date copyright10/5/2021 12:00:00 AM
    date issued2021
    identifier issn0195-0738
    identifier otherjert_143_12_120911.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278477
    description abstractA natural gas-fueled homogeneous charge compression ignition (HCCI) engine is coupled to an exhaust gas operated turbine driven two-phase ejector cycle to generate power and cooling energy, simultaneously. By establishing a thermodynamic model, the simulation of the proposed system and its parametric analyses are conducted. Energetic and exergetic investigations are carried out to study the role of equivalence ratio, engine speed, condenser temperature, refrigeration evaporator temperature, air-conditioning evaporator temperature, and ejector nozzle efficiency on the thermodynamic performance parameters of the combined cycle. The analysis of two-phase ejector cooling cycle using three working fluids including R717, R290, and R600a is conducted. Results reveal that the thermal efficiency of HCCI engine is increased from 47.44% to 49.94%, and for the R600a operated combined cycle it is increased from 60.05% to 63.26% when the equivalence ratio is promoted from 0.3 to 0.6. Distribution of fuel exergy results show that out of 100% exergy input, in case of R717 operated combined cycle, 139.79 kW (38.72%) is the total exergy output, and 164.21 kW (45.49%) and 57 kW (15.79%) are the values for exergy destruction and exergy losses. It is further shown that change in refrigerant minorly influence the percentages of exergy distribution.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInvestigation of a Combined Refrigeration and Air Conditioning System Based on Two-Phase Ejector Driven by Exhaust Gases of Natural Gas Fueled Homogeneous Charge Compression Ignition Engine
    typeJournal Paper
    journal volume143
    journal issue12
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.4052248
    journal fristpage0120911-1
    journal lastpage0120911-15
    page15
    treeJournal of Energy Resources Technology:;2021:;volume( 143 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian