Show simple item record

contributor authorElenes, Egleide Y.
contributor authorMehta, Jason N.
contributor authorHsu, Fang-Chi
contributor authorWhitlow, Christopher T.
contributor authorDebinski, Waldermar
contributor authorRossmeisl, John
contributor authorTatter, Stephen
contributor authorRylander, Christopher G.
date accessioned2022-02-05T22:40:38Z
date available2022-02-05T22:40:38Z
date copyright12/2/2020 12:00:00 AM
date issued2020
identifier issn2572-7958
identifier otherjesmdt_004_01_011003.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277959
description abstractStandard treatment for glioblastoma is noncurative and only partially effective. Convection-enhanced delivery (CED) was developed as an alternative approach for effective loco-regional delivery of drugs via a small catheter inserted into the diseased brain. However, previous CED clinical trials revealed the need for improved catheters for controlled and satisfactory distribution of therapeutics. In this study, the arborizing catheter, consisting of six infusion ports, was compared to a reflux-preventing single-port catheter. Infusions of iohexol at a flow rate of 1 μL/min/microneedle were performed, using the arborizing catheter on one hemisphere and a single-port catheter on the contralateral hemisphere of excised pig brains. The volume dispersed (Vd) of the contrast agent was quantified for each catheter. Vd for the arborizing catheter was significantly higher than for the single-port catheter, 2235.8 ± 569.7 mm3 and 382.2 ± 243.0 mm3, respectively (n = 7). Minimal reflux was observed; however, high Vd values were achieved with the arborizing catheter. With simultaneous infusion using multiple ports of the arborizing catheter, high Vd was achieved at a low infusion rate. Thus, the arborizing catheter promises a highly desirable large volume of distribution of drugs delivered to the brain for the purpose of treating brain tumors.
publisherThe American Society of Mechanical Engineers (ASME)
titleConvection-Enhanced Arborizing Catheter System Improves Local/Regional Delivery of Infusates Versus a Single-Port Catheter in Ex Vivo Porcine Brain Tissue
typeJournal Paper
journal volume4
journal issue1
journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
identifier doi10.1115/1.4048935
journal fristpage011003-1
journal lastpage011003-9
page9
treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2020:;volume( 004 ):;issue: 001
contenttypeFulltext