YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Correlation of Computational Instantaneous Wave-Free Ratio With Fractional Flow Reserve for Intermediate Multivessel Coronary Disease

    Source: Journal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 005::page 051011-1
    Author:
    Ghorbanniahassankiadeh, Arash
    ,
    Marks, David S.
    ,
    LaDisa, John F., Jr.
    DOI: 10.1115/1.4049746
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study computationally assesses the accuracy of an instantaneous wave-free ratio (iFR) threshold range compared to standard modalities such as fractional flow reserve (FFR) and coronary flow reserve (CFR) for multiple intermediate lesions near the left main (LM) coronary bifurcation. iFR is an adenosine-independent index encouraged for assessment of coronary artery disease (CAD), but different thresholds are debated. This becomes particularly challenging in cases of multivessel disease when sensitivity to downstream lesions is unclear. Idealized LM coronary arteries with 34 different intermediate stenoses were created and categorized (Medina) as single and multiple lesion groups. Computational fluid dynamics modeling was performed with physiologic boundary conditions using an open-source software (simvascular1) to solve the time-dependent Navier–Stokes equations. A strong linear relationship between iFR and FFR was observed among studied models, indicating computational iFR values of 0.92 and 0.93 are statistically equivalent to an FFR of 0.80 in single and multiple lesion groups, respectively. At the clinical FFR value (i.e., 0.8), a triple-lesion group had smaller CFR compared to the single and double lesion groups (e.g., triple = 3.077 versus single = 3.133 and double = 3.132). In general, the effect of additional intermediate downstream lesions (minimum lumen area > 3 mm2) was not statistically significant for iFR and CFR. A computational iFR of 0.92 best predicts an FFR of 0.80 and may be recommended as threshold criteria for computational assessment of LM stenosis following additional validation using patient-specific models.
    • Download: (1.180Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Correlation of Computational Instantaneous Wave-Free Ratio With Fractional Flow Reserve for Intermediate Multivessel Coronary Disease

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277958
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorGhorbanniahassankiadeh, Arash
    contributor authorMarks, David S.
    contributor authorLaDisa, John F., Jr.
    date accessioned2022-02-05T22:40:36Z
    date available2022-02-05T22:40:36Z
    date copyright3/8/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_143_05_051011.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277958
    description abstractThis study computationally assesses the accuracy of an instantaneous wave-free ratio (iFR) threshold range compared to standard modalities such as fractional flow reserve (FFR) and coronary flow reserve (CFR) for multiple intermediate lesions near the left main (LM) coronary bifurcation. iFR is an adenosine-independent index encouraged for assessment of coronary artery disease (CAD), but different thresholds are debated. This becomes particularly challenging in cases of multivessel disease when sensitivity to downstream lesions is unclear. Idealized LM coronary arteries with 34 different intermediate stenoses were created and categorized (Medina) as single and multiple lesion groups. Computational fluid dynamics modeling was performed with physiologic boundary conditions using an open-source software (simvascular1) to solve the time-dependent Navier–Stokes equations. A strong linear relationship between iFR and FFR was observed among studied models, indicating computational iFR values of 0.92 and 0.93 are statistically equivalent to an FFR of 0.80 in single and multiple lesion groups, respectively. At the clinical FFR value (i.e., 0.8), a triple-lesion group had smaller CFR compared to the single and double lesion groups (e.g., triple = 3.077 versus single = 3.133 and double = 3.132). In general, the effect of additional intermediate downstream lesions (minimum lumen area > 3 mm2) was not statistically significant for iFR and CFR. A computational iFR of 0.92 best predicts an FFR of 0.80 and may be recommended as threshold criteria for computational assessment of LM stenosis following additional validation using patient-specific models.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCorrelation of Computational Instantaneous Wave-Free Ratio With Fractional Flow Reserve for Intermediate Multivessel Coronary Disease
    typeJournal Paper
    journal volume143
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4049746
    journal fristpage051011-1
    journal lastpage051011-7
    page7
    treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian