Performance Evaluation of a Single-Stage Two-Bed Adsorption Chiller With Desalination FunctionSource: Journal of Energy Resources Technology:;2020:;volume( 143 ):;issue: 008::page 082101-1Author:Sztekler, Karol
,
Kalawa, Wojciech
,
Nowak, Wojciech
,
Mika, Łukasz
,
Krzywański, Jarosław
,
Grabowska, Karolina
,
Sosnowski, Marcin
,
Alharbi, Ahmed A.
DOI: 10.1115/1.4048771Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Energy efficiency is one of the most important topics nowadays. It is strictly related to the problem of energy demand, energy policy, environmental pollution, and economic issues. Because of the technological development, using more advanced processes in almost every part of industry and increasing demands both for a high standard of living and simplification of processes, the energy demand is growing. This can be observed, e.g., in the building sector—air conditioning is present in almost every new building and people expect high quality thermal conditions. At the same time, many technological processes result in dissipating energy to the environment. Energy efficiency can be increased and operation costs reduced by using waste heat in other processes. One of the possibilities is to use sorption chillers to produce cool and desalinated water. Low temperature waste heat is not easy to utilize because of low energy potential. Using adsorption chillers in low temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of experimental study carried out on three-bed adsorption chiller with desalination, using silica gel and water as the working pair. The chiller was equipped with plate-fin tube heat exchanger filled with silica gel with a grain size of 0.5–1.5 mm. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stand scheme and description were presented. All results were obtained during a few hours test with stable temperature conditions in the range of 55–85 °C for the heating water.
|
Collections
Show full item record
contributor author | Sztekler, Karol | |
contributor author | Kalawa, Wojciech | |
contributor author | Nowak, Wojciech | |
contributor author | Mika, Łukasz | |
contributor author | Krzywański, Jarosław | |
contributor author | Grabowska, Karolina | |
contributor author | Sosnowski, Marcin | |
contributor author | Alharbi, Ahmed A. | |
date accessioned | 2022-02-05T22:39:18Z | |
date available | 2022-02-05T22:39:18Z | |
date copyright | 11/4/2020 12:00:00 AM | |
date issued | 2020 | |
identifier issn | 0195-0738 | |
identifier other | jert_143_8_082101.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4277916 | |
description abstract | Energy efficiency is one of the most important topics nowadays. It is strictly related to the problem of energy demand, energy policy, environmental pollution, and economic issues. Because of the technological development, using more advanced processes in almost every part of industry and increasing demands both for a high standard of living and simplification of processes, the energy demand is growing. This can be observed, e.g., in the building sector—air conditioning is present in almost every new building and people expect high quality thermal conditions. At the same time, many technological processes result in dissipating energy to the environment. Energy efficiency can be increased and operation costs reduced by using waste heat in other processes. One of the possibilities is to use sorption chillers to produce cool and desalinated water. Low temperature waste heat is not easy to utilize because of low energy potential. Using adsorption chillers in low temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of experimental study carried out on three-bed adsorption chiller with desalination, using silica gel and water as the working pair. The chiller was equipped with plate-fin tube heat exchanger filled with silica gel with a grain size of 0.5–1.5 mm. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stand scheme and description were presented. All results were obtained during a few hours test with stable temperature conditions in the range of 55–85 °C for the heating water. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Performance Evaluation of a Single-Stage Two-Bed Adsorption Chiller With Desalination Function | |
type | Journal Paper | |
journal volume | 143 | |
journal issue | 8 | |
journal title | Journal of Energy Resources Technology | |
identifier doi | 10.1115/1.4048771 | |
journal fristpage | 082101-1 | |
journal lastpage | 082101-7 | |
page | 7 | |
tree | Journal of Energy Resources Technology:;2020:;volume( 143 ):;issue: 008 | |