YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Stent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period

    Source: Journal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003::page 031009-1
    Author:
    Santos, Gabriel B.
    ,
    Oliveira, Iago
    ,
    Gasche, José L.
    ,
    Militzer, Julio
    ,
    Baccin, Carlos E.
    DOI: 10.1115/1.4048645
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Stenting has become an important adjunctive tool for assisting coil embolization in complex-shaped intracranial aneurysms. However, as a secondary effect, stent deployment has been related to both immediate and delayed remodeling of the local vasculature. Recent studies have demonstrated that this phenomenon may assume different roles depending on the treatment stage. However, the extent of such event on the intra-aneurysmal hemodynamics is still unclear; especially when performing two-step stent-assisted coiling (SAC). Therefore, we performed computational fluid dynamics (CFD) analysis of the blood flow in four bifurcation aneurysms focusing on the stent healing period found in SAC as a two-step maneuver. Our results show that by changing the local vasculature, the intra-aneurysmal hemodynamics changes considerably. However, even though changes do occur, they were not consistent among the cases. Furthermore, by changing the local vasculature not only the shear levels change but also the shear distribution on the aneurysm surface. Additionally, a geometric analysis alone can mislead the estimation of the novel hemodynamic environment after vascular remodeling, especially in the presence of mixing streams. Therefore, although the novel local vasculature might induce an improved hemodynamic environment, it is also plausible to expect that adverse hemodynamic conditions might occur. This could pose a particularly delicate condition since the aneurysm surface remains completely exposed to the novel hemodynamic environment during the stent healing period. Finally, our study emphasizes that vascular remodeling should be considered when assessing the hemodynamics in aneurysms treated with stents, especially when evaluating the earlier stages of the treatment process.
    • Download: (10.71Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Stent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277570
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSantos, Gabriel B.
    contributor authorOliveira, Iago
    contributor authorGasche, José L.
    contributor authorMilitzer, Julio
    contributor authorBaccin, Carlos E.
    date accessioned2022-02-05T22:27:35Z
    date available2022-02-05T22:27:35Z
    date copyright12/10/2020 12:00:00 AM
    date issued2020
    identifier issn0148-0731
    identifier otherbio_143_03_031009.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277570
    description abstractStenting has become an important adjunctive tool for assisting coil embolization in complex-shaped intracranial aneurysms. However, as a secondary effect, stent deployment has been related to both immediate and delayed remodeling of the local vasculature. Recent studies have demonstrated that this phenomenon may assume different roles depending on the treatment stage. However, the extent of such event on the intra-aneurysmal hemodynamics is still unclear; especially when performing two-step stent-assisted coiling (SAC). Therefore, we performed computational fluid dynamics (CFD) analysis of the blood flow in four bifurcation aneurysms focusing on the stent healing period found in SAC as a two-step maneuver. Our results show that by changing the local vasculature, the intra-aneurysmal hemodynamics changes considerably. However, even though changes do occur, they were not consistent among the cases. Furthermore, by changing the local vasculature not only the shear levels change but also the shear distribution on the aneurysm surface. Additionally, a geometric analysis alone can mislead the estimation of the novel hemodynamic environment after vascular remodeling, especially in the presence of mixing streams. Therefore, although the novel local vasculature might induce an improved hemodynamic environment, it is also plausible to expect that adverse hemodynamic conditions might occur. This could pose a particularly delicate condition since the aneurysm surface remains completely exposed to the novel hemodynamic environment during the stent healing period. Finally, our study emphasizes that vascular remodeling should be considered when assessing the hemodynamics in aneurysms treated with stents, especially when evaluating the earlier stages of the treatment process.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleStent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period
    typeJournal Paper
    journal volume143
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4048645
    journal fristpage031009-1
    journal lastpage031009-10
    page10
    treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian