    Analytical Modeling for Vapor Condensation in the Presence of Noncondensable Gas and Experimental Validation

    Source: Journal of Heat Transfer:;2020:;volume( 143 ):;issue: 001::page 011601-1
    Author:
    Zhang, Wei
    ,
    Wang, Suilin
    ,
    Lianbo, Mu
    DOI: 10.1115/1.4048251
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The sensible and latent heat transfer are two essential considerations in investigating vapor condensation in the presence of noncondensable gases. In this paper, a new model for filmwise condensation heat transfer was developed using similarity-based solution. The expression of gas–liquid interfacial temperature, film thickness, and heat transfer coefficient were derived and calculated, respectively. The analytical results showed that the temperature difference between gas–liquid interfacial and cooling surface is decreased as there is an increase in cooling surface temperature. In addition, the forced-convective condensation heat transfer and film thickness on the vertical surface were experimentally carried out. The proportion of latent heat is 62–67% and relatively larger than sensible heat in the range of wall temperature (17–32.5 °C). The experimental film thickness is less than analytical film thickness by 2–10%. It is because that the liquid film may evaporate back to water vapor in the neighboring wall area due to high temperature of flue gas. Further, a new nondimensional correlation of condensation heat transfer of flue gas is fitted with Nu = 0.62Re0.5Ja0.67 and applicable range is Re = 1000–2500, Ja = 1.7–4.4. The fitting shows a good agreement between experimental and correlated values except some points in the low Nu number. The model proposed is applicable to predict the temperature and velocity distribution for condensation heat and mass transfer of multicomponent gases.
    • Download: (2.614Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Analytical Modeling for Vapor Condensation in the Presence of Noncondensable Gas and Experimental Validation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4277511
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorZhang, Wei
    contributor authorWang, Suilin
    contributor authorLianbo, Mu
    date accessioned2022-02-05T22:25:26Z
    date available2022-02-05T22:25:26Z
    date copyright10/7/2020 12:00:00 AM
    date issued2020
    identifier issn0022-1481
    identifier otherht_143_01_011601.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277511
    description abstractThe sensible and latent heat transfer are two essential considerations in investigating vapor condensation in the presence of noncondensable gases. In this paper, a new model for filmwise condensation heat transfer was developed using similarity-based solution. The expression of gas–liquid interfacial temperature, film thickness, and heat transfer coefficient were derived and calculated, respectively. The analytical results showed that the temperature difference between gas–liquid interfacial and cooling surface is decreased as there is an increase in cooling surface temperature. In addition, the forced-convective condensation heat transfer and film thickness on the vertical surface were experimentally carried out. The proportion of latent heat is 62–67% and relatively larger than sensible heat in the range of wall temperature (17–32.5 °C). The experimental film thickness is less than analytical film thickness by 2–10%. It is because that the liquid film may evaporate back to water vapor in the neighboring wall area due to high temperature of flue gas. Further, a new nondimensional correlation of condensation heat transfer of flue gas is fitted with Nu = 0.62Re0.5Ja0.67 and applicable range is Re = 1000–2500, Ja = 1.7–4.4. The fitting shows a good agreement between experimental and correlated values except some points in the low Nu number. The model proposed is applicable to predict the temperature and velocity distribution for condensation heat and mass transfer of multicomponent gases.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAnalytical Modeling for Vapor Condensation in the Presence of Noncondensable Gas and Experimental Validation
    typeJournal Paper
    journal volume143
    journal issue1
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4048251
    journal fristpage011601-1
    journal lastpage011601-12
    page12
    treeJournal of Heat Transfer:;2020:;volume( 143 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian