Show simple item record

contributor authorSterzinger, P. Z.
contributor authorMerli, F.
contributor authorPeters, A.
contributor authorBehre, S.
contributor authorHeitmeir, F.
contributor authorGöttlich, E.
date accessioned2022-02-05T22:08:23Z
date available2022-02-05T22:08:23Z
date copyright4/13/2021 12:00:00 AM
date issued2021
identifier issn0889-504X
identifier otherturbo_143_5_051011.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276992
description abstractPrevious studies have indicated a potential for improving the performance of a turbine center frame (TCF) duct by optimizing the clocking position between the high-pressure turbine (HPT) vanes and TCF struts. To assess the impact of clocking on the performance, a new test vehicle with a clockable ratio of HPT vanes to TCF struts, consisting of an HPT stage (aerodynamically representative of the second-stage HPT engine), a TCF duct with nonturning struts, and a first-stage low-pressure turbine vane, was designed and tested in the transonic test turbine facility (TTTF) at Graz University of Technology. This article quantifies the performance impact of clocking and describes the mechanisms causing TCF flow field changes, leveraging both experimental and numerical data. Other areas in the TCF duct impacted by the choice of the HPT vane circumferential position including the strength of unsteady HPT-TCF interaction modes, TCF strut incidence changes, and carryover effects to the first low-pressure turbine (LPT) vane are additionally highlighted. Five-hole-probe (5HP) area traverses and kielhead-rake traverses were used to assess the flow field at the TCF exit and to calculate the pressure loss. The flow field at the TCF exit shows significant differences depending on the circumferential position of the HPT vane. A relative performance benefit of 5% was achieved. A series of unsteady RANS simulations were performed to support the measured results, understand, and characterize the relevant loss mechanisms. The observed performance improvement was related to interaction between the HPT secondary-flow structures and the TCF struts. The impact of the HPT vane clocking on the unsteady flow field downstream of the TCF was investigated using fast-response aerodynamic pressure probe (FRAPP) area traverses and analyzed by means of modal decomposition. In this way, the individual azimuthal modes were ranked by their amplitude, and a dependency of the clocking position was observed and quantified.
publisherThe American Society of Mechanical Engineers (ASME)
titleImpact of Turbine-Strut Clocking on the Performance of a Turbine Center Frame
typeJournal Paper
journal volume143
journal issue5
journal titleJournal of Turbomachinery
identifier doi10.1115/1.4050145
journal fristpage051011-1
journal lastpage051011-13
page13
treeJournal of Turbomachinery:;2021:;volume( 143 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record