Comparison of Neutron-Gamma Separation Qualities of Various Organic Scintillation Materials and Liquid Scintillator LSB-200Source: Journal of Nuclear Engineering and Radiation Science:;2020:;volume( 007 ):;issue: 002::page 024502-1Author:Matěj, Zdeněk
,
Mravec, Filip
,
Jančár, Aleš
,
Košťál, Michal
,
Kučera, František
,
Cvachovec, František
,
Prenosil, Václav
,
Kopecký, Zdeněk
,
Čulen, Jiří
,
Pecák, Oldřich
DOI: 10.1115/1.4048767Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog–digital converters with a resolution of 12 bits and sampling frequency 500 × 106 Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented.
|
Show full item record
contributor author | Matěj, Zdeněk | |
contributor author | Mravec, Filip | |
contributor author | Jančár, Aleš | |
contributor author | Košťál, Michal | |
contributor author | Kučera, František | |
contributor author | Cvachovec, František | |
contributor author | Prenosil, Václav | |
contributor author | Kopecký, Zdeněk | |
contributor author | Čulen, Jiří | |
contributor author | Pecák, Oldřich | |
date accessioned | 2022-02-05T21:53:16Z | |
date available | 2022-02-05T21:53:16Z | |
date copyright | 10/30/2020 12:00:00 AM | |
date issued | 2020 | |
identifier issn | 2332-8983 | |
identifier other | ners_007_02_024502.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4276521 | |
description abstract | In this work, we compare the pulse-shape discrimination (PSD) properties of newly developed liquid scintillator LSB-200, EJ-299-33A, BC-501A, stilbene, p-terphenyl, and Hidex Aqualight in neutron field generated by the LVR-15 reactor with silicon filter utilization. Pulses from the scintillators are processed by the Neutron-Gamma spectrometer. This spectrometric system with fast digitizer card contains two analog–digital converters with a resolution of 12 bits and sampling frequency 500 × 106 Hz. For photomultiplier linearity improvement, the active divider has been used. Measured data from scintillators have been processed using the integration method and compared. The results are presented. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Comparison of Neutron-Gamma Separation Qualities of Various Organic Scintillation Materials and Liquid Scintillator LSB-200 | |
type | Journal Paper | |
journal volume | 7 | |
journal issue | 2 | |
journal title | Journal of Nuclear Engineering and Radiation Science | |
identifier doi | 10.1115/1.4048767 | |
journal fristpage | 024502-1 | |
journal lastpage | 024502-6 | |
page | 6 | |
tree | Journal of Nuclear Engineering and Radiation Science:;2020:;volume( 007 ):;issue: 002 | |
contenttype | Fulltext |