YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Non-Newtonian Blood Modeling in Intracranial Aneurysm Hemodynamics: Impact on the Wall Shear Stress and Oscillatory Shear Index Metrics for Ruptured and Unruptured Cases

    Source: Journal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007::page 071006-1
    Author:
    Oliveira, Iago L.
    ,
    Santos, Gabriel B.
    ,
    Gasche, José L.
    ,
    Militzer, Julio
    ,
    Baccin, Carlos E.
    DOI: 10.1115/1.4050539
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: When simulating blood flow in intracranial aneurysms (IAs), the Newtonian model seems to be ubiquitous. However, analyzing the results from the few studies on this subject, the doubt remains on whether it is necessary to use non-Newtonian models in computational fluid dynamics (CFD) simulations of cerebral vascular flows. The objective of this study is to investigate whether different rheology models would influence the hemodynamic parameters related to the wall shear stress (WSS) for ruptured and unruptured IA cases, especially because ruptured aneurysms normally have morphological features, such as lobular regions and blebs, that could trigger non-Newtonian phenomena in the blood flow due to low shear rates. Using CFD in an open-source framework, we simulated four ruptured and four unruptured patient-specific aneurysms to assess the influence of the blood modeling on the main hemodynamic variables associated with aneurysm formation, growth, and rupture. Results for WSS and oscillatory shear index (OSI) and their metrics were obtained using Casson and Carreau–Yasuda non-Newtonian models and were compared with those obtained using the Newtonian model. We found that all differences between non-Newtonian and the Newtonian models were consistent among all cases irrespective of their rupture status. We further found that the WSS at peak systole is overestimated by more than 50% by using the non-Newtonian models, but its metrics based on time and surface averaged values are less affected—the maximum relative difference among the cases is 7% for the Casson model. On the other hand, the surface-averaged OSI is underestimated by more than 30% by the non-Newtonian models. These results suggest that it is recommended to investigate different blood rheology models in IAs simulations when specific parameters to characterize the flow are needed, such as peak-systole WSS and OSI.
    • Download: (2.402Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Non-Newtonian Blood Modeling in Intracranial Aneurysm Hemodynamics: Impact on the Wall Shear Stress and Oscillatory Shear Index Metrics for Ruptured and Unruptured Cases

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276267
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorOliveira, Iago L.
    contributor authorSantos, Gabriel B.
    contributor authorGasche, José L.
    contributor authorMilitzer, Julio
    contributor authorBaccin, Carlos E.
    date accessioned2022-02-05T21:45:04Z
    date available2022-02-05T21:45:04Z
    date copyright4/5/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_143_07_071006.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276267
    description abstractWhen simulating blood flow in intracranial aneurysms (IAs), the Newtonian model seems to be ubiquitous. However, analyzing the results from the few studies on this subject, the doubt remains on whether it is necessary to use non-Newtonian models in computational fluid dynamics (CFD) simulations of cerebral vascular flows. The objective of this study is to investigate whether different rheology models would influence the hemodynamic parameters related to the wall shear stress (WSS) for ruptured and unruptured IA cases, especially because ruptured aneurysms normally have morphological features, such as lobular regions and blebs, that could trigger non-Newtonian phenomena in the blood flow due to low shear rates. Using CFD in an open-source framework, we simulated four ruptured and four unruptured patient-specific aneurysms to assess the influence of the blood modeling on the main hemodynamic variables associated with aneurysm formation, growth, and rupture. Results for WSS and oscillatory shear index (OSI) and their metrics were obtained using Casson and Carreau–Yasuda non-Newtonian models and were compared with those obtained using the Newtonian model. We found that all differences between non-Newtonian and the Newtonian models were consistent among all cases irrespective of their rupture status. We further found that the WSS at peak systole is overestimated by more than 50% by using the non-Newtonian models, but its metrics based on time and surface averaged values are less affected—the maximum relative difference among the cases is 7% for the Casson model. On the other hand, the surface-averaged OSI is underestimated by more than 30% by the non-Newtonian models. These results suggest that it is recommended to investigate different blood rheology models in IAs simulations when specific parameters to characterize the flow are needed, such as peak-systole WSS and OSI.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNon-Newtonian Blood Modeling in Intracranial Aneurysm Hemodynamics: Impact on the Wall Shear Stress and Oscillatory Shear Index Metrics for Ruptured and Unruptured Cases
    typeJournal Paper
    journal volume143
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4050539
    journal fristpage071006-1
    journal lastpage071006-12
    page12
    treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian