YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Methodology to Evaluate the Effects of Kinematic Measurement Uncertainties on Knee Ligament Properties Estimated From Laxity Measurements

    Source: Journal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006::page 061003-1
    Author:
    Andersen, Michael Skipper
    ,
    Dzialo, Christine Mary
    ,
    Marra, Marco Antonio
    ,
    Pedersen, Dennis
    DOI: 10.1115/1.4050027
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Ligaments are important joint stabilizers but assessing their mechanical properties remain challenging. We developed a methodology to investigate the effects of kinematic measurement uncertainty during laxity tests on optimization-based estimation of ligament properties. We applied this methodology to a subject-specific knee model with known ligament properties as inputs and compared the estimated to the known knee ligament properties under the influence of noise. Four different sets of laxity tests were simulated with an increasing number of load cases, capturing anterior/posterior, varus/valgus, and internal/external rotation loads at 0 deg and 30 deg of knee flexion. 20 samples of uniform random noise ([−0.5,0.5] mm and degrees) were added to each set and fed into an optimization routine that subsequently estimated the ligament properties based on the noise targets. We found a large range of estimated ligament properties (stiffness ranges of 5.97 kN, 7.64 kN, 8.72 kN, and 3.86 kN; reference strain ranges of 3.11%, 2.53%, 1.88%, and 1.58% for anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medical collateral ligament (MCL), and lateral collateral ligament (LCL), respectively) for three sets of laxity tests, including up to 22 load cases. A set of laxity tests with 60 load cases kept the stiffness and reference strain ranges below 470 N per unit strain and 0.85%, respectively. These results illustrate that kinematic measurement noise have a large impact on estimated ligament properties and we recommend that future studies assess and report both the estimated ligament properties and the associated uncertainties due to kinematic measurement noise.
    • Download: (1017.Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Methodology to Evaluate the Effects of Kinematic Measurement Uncertainties on Knee Ligament Properties Estimated From Laxity Measurements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4276057
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAndersen, Michael Skipper
    contributor authorDzialo, Christine Mary
    contributor authorMarra, Marco Antonio
    contributor authorPedersen, Dennis
    date accessioned2022-02-05T21:38:58Z
    date available2022-02-05T21:38:58Z
    date copyright3/9/2021 12:00:00 AM
    date issued2021
    identifier issn0148-0731
    identifier otherbio_143_06_061003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276057
    description abstractLigaments are important joint stabilizers but assessing their mechanical properties remain challenging. We developed a methodology to investigate the effects of kinematic measurement uncertainty during laxity tests on optimization-based estimation of ligament properties. We applied this methodology to a subject-specific knee model with known ligament properties as inputs and compared the estimated to the known knee ligament properties under the influence of noise. Four different sets of laxity tests were simulated with an increasing number of load cases, capturing anterior/posterior, varus/valgus, and internal/external rotation loads at 0 deg and 30 deg of knee flexion. 20 samples of uniform random noise ([−0.5,0.5] mm and degrees) were added to each set and fed into an optimization routine that subsequently estimated the ligament properties based on the noise targets. We found a large range of estimated ligament properties (stiffness ranges of 5.97 kN, 7.64 kN, 8.72 kN, and 3.86 kN; reference strain ranges of 3.11%, 2.53%, 1.88%, and 1.58% for anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medical collateral ligament (MCL), and lateral collateral ligament (LCL), respectively) for three sets of laxity tests, including up to 22 load cases. A set of laxity tests with 60 load cases kept the stiffness and reference strain ranges below 470 N per unit strain and 0.85%, respectively. These results illustrate that kinematic measurement noise have a large impact on estimated ligament properties and we recommend that future studies assess and report both the estimated ligament properties and the associated uncertainties due to kinematic measurement noise.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Methodology to Evaluate the Effects of Kinematic Measurement Uncertainties on Knee Ligament Properties Estimated From Laxity Measurements
    typeJournal Paper
    journal volume143
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4050027
    journal fristpage061003-1
    journal lastpage061003-7
    page7
    treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian