    Numerical Characterization of Viscous Heat Dissipation Rate in Oscillatory Air Flow

    Source: Journal of Heat Transfer:;2020:;volume( 142 ):;issue: 001::page 011801-1
    Author:
    Jalil, S. M.
    DOI: 10.1115/1.4045173
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The effect of viscous heat dissipation (VHD) in raising the temperature field of incompressible oscillatory air flow is studied numerically. A threshold is established for when the viscous heat dissipation term in the thermal energy equation changes or does not change the temperature field for the case of oscillatory air flow in a tube connecting two reservoirs. This new criterion has not been specified clearly in earlier oscillatory flow research. According to the defined threshold and when VHD is important, the effect of dissipative bulk heating can be described by a proposed correlation in terms of Womersley number (Wo) and axial tidal displacement (ΔZ) of the oscillatory fluid. These results are determined using two-dimensional (2D) numerical simulations of laminar oscillatory air flow (Pr = 0.7) for different adiabatic unconductive tube-reservoirs' systems configurations over a wide range of oscillatory frequencies and tidal displacements. It is found that the low amount of fluid kinetic energy, which is converted into internal energy, is not sufficient to significantly heat up the fluid at a low rate of the viscous work. Therefore, the effect of viscous heat dissipation in oscillatory air flow can be ignored only below a specific limit of unsteadiness depending on Womersley number and axial tidal displacement. Also, the results showed that the VHD becomes more significant with increasing (Wo) and (ΔZ).
    • Download: (2.754Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Numerical Characterization of Viscous Heat Dissipation Rate in Oscillatory Air Flow

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4275584
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorJalil, S. M.
    date accessioned2022-02-04T22:51:37Z
    date available2022-02-04T22:51:37Z
    date copyright1/1/2020 12:00:00 AM
    date issued2020
    identifier issn0022-1481
    identifier otherht_142_01_011801.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275584
    description abstractThe effect of viscous heat dissipation (VHD) in raising the temperature field of incompressible oscillatory air flow is studied numerically. A threshold is established for when the viscous heat dissipation term in the thermal energy equation changes or does not change the temperature field for the case of oscillatory air flow in a tube connecting two reservoirs. This new criterion has not been specified clearly in earlier oscillatory flow research. According to the defined threshold and when VHD is important, the effect of dissipative bulk heating can be described by a proposed correlation in terms of Womersley number (Wo) and axial tidal displacement (ΔZ) of the oscillatory fluid. These results are determined using two-dimensional (2D) numerical simulations of laminar oscillatory air flow (Pr = 0.7) for different adiabatic unconductive tube-reservoirs' systems configurations over a wide range of oscillatory frequencies and tidal displacements. It is found that the low amount of fluid kinetic energy, which is converted into internal energy, is not sufficient to significantly heat up the fluid at a low rate of the viscous work. Therefore, the effect of viscous heat dissipation in oscillatory air flow can be ignored only below a specific limit of unsteadiness depending on Womersley number and axial tidal displacement. Also, the results showed that the VHD becomes more significant with increasing (Wo) and (ΔZ).
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNumerical Characterization of Viscous Heat Dissipation Rate in Oscillatory Air Flow
    typeJournal Paper
    journal volume142
    journal issue1
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4045173
    journal fristpage011801-1
    journal lastpage011801-10
    page10
    treeJournal of Heat Transfer:;2020:;volume( 142 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian