    Investigation of an Energy Source Temperature for NH3 + NaSCN and NH3 + LiNO3 Absorption Refrigeration Systems

    Source: Journal of Energy Resources Technology:;2020:;volume( 142 ):;issue: 010::page 0104502-1
    Author:
    Modi, Nishant
    ,
    Pandya, Bhargav
    ,
    Patel, Jatin
    DOI: 10.1115/1.4047017
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper evaluates the energy source temperature for novel salts based ammonia/sodium thiocyanate (NH3 + NaSCN) and ammonia/lithium nitrate (NH3 + LiNO3) absorption refrigeration systems. Minimum energy source temperature (cutoff) required to initiate the cooling, critical energy source temperature for optimized thermodynamic performance and possible maximum energy source temperature to avoid crystallization have been determined, and empirical correlations are developed to facilitate continuous operation of the system. A comparison of cutoff energy source temperature depicts that the NH3 + NaSCN pair requires averagely 6 –7 °C higher cutoff temperature compared with the NH3 + LiNO3 pair. Contradictory to this, the maximum coefficient of performance (COP) of the NH3 + NaSCN pair is 7.02% higher than that the NH3 + LiNO3 pair. However, NH3 + NaSCN pair operates in a very narrow range of energy source temperature. From the P − T − X diagram, the crystallization phenomenon is clarified and the maximum energy source temperature has been determined beyond which the system would not function due to crystallization problems. For −10 °C evaporator temperature, the energy source temperature should be controlled between 87 °C and 115 °C for the NH3 + NaSCN pair and between 80 °C and 147 °C for the NH3 + LiNO3 pair.
    • Download: (811.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Investigation of an Energy Source Temperature for NH3 + NaSCN and NH3 + LiNO3 Absorption Refrigeration Systems

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274956
    Collections
    • Journal of Energy Resources Technology

    Show full item record

    contributor authorModi, Nishant
    contributor authorPandya, Bhargav
    contributor authorPatel, Jatin
    date accessioned2022-02-04T22:08:26Z
    date available2022-02-04T22:08:26Z
    date copyright5/26/2020 12:00:00 AM
    date issued2020
    identifier issn0195-0738
    identifier otherjert_142_10_104502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274956
    description abstractThis paper evaluates the energy source temperature for novel salts based ammonia/sodium thiocyanate (NH3 + NaSCN) and ammonia/lithium nitrate (NH3 + LiNO3) absorption refrigeration systems. Minimum energy source temperature (cutoff) required to initiate the cooling, critical energy source temperature for optimized thermodynamic performance and possible maximum energy source temperature to avoid crystallization have been determined, and empirical correlations are developed to facilitate continuous operation of the system. A comparison of cutoff energy source temperature depicts that the NH3 + NaSCN pair requires averagely 6 –7 °C higher cutoff temperature compared with the NH3 + LiNO3 pair. Contradictory to this, the maximum coefficient of performance (COP) of the NH3 + NaSCN pair is 7.02% higher than that the NH3 + LiNO3 pair. However, NH3 + NaSCN pair operates in a very narrow range of energy source temperature. From the P − T − X diagram, the crystallization phenomenon is clarified and the maximum energy source temperature has been determined beyond which the system would not function due to crystallization problems. For −10 °C evaporator temperature, the energy source temperature should be controlled between 87 °C and 115 °C for the NH3 + NaSCN pair and between 80 °C and 147 °C for the NH3 + LiNO3 pair.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInvestigation of an Energy Source Temperature for NH3 + NaSCN and NH3 + LiNO3 Absorption Refrigeration Systems
    typeJournal Paper
    journal volume142
    journal issue10
    journal titleJournal of Energy Resources Technology
    identifier doi10.1115/1.4047017
    journal fristpage0104502-1
    journal lastpage0104502-7
    page7
    treeJournal of Energy Resources Technology:;2020:;volume( 142 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian